background image

4

OPERATION INSTRUCTION

NOTES: When the welder works for a long time, the high

temperature indicator will light. This means the inside

temperature has exceeded its standard. And you must turn

off the power immediately for a period until it recovers.

   • You have to wear canvas overalls and face mask

      to prevent from arc light and heat radiation.
   • Vibration screen should be laid out to prevent others from

      arc light.
   • Inflammable and explosive stuffs are not allowed

      to pile up. All the connections must be right, reliable.

Procedure

 a) Connect to the power switch digital ammeter lights on.
 b) To adjust the current potentiometer to the required

      value of the welding.
 c) Pick up electrode holder, and point at the welding edge.

     Then put the electrode on the workpiece, you can start

     welding.

Electrode Replacement

When the electrode is left only 2~3cm away from the holder,

you have to replace new one to go on working.

NOTES: When the electrodes combustion is in process at

high heat, do not touch it with bare hands while replacing

it. Besides, the electrode head down should be unified in 

a metal container. And the cover coating should not be

caught by the holder. Scratch gently when igniting the arc,

otherwise it is easy to come across the phenomenon

of sticking electrode.

Slag Removal

After finishing work, you should remove the slag with specific

knock residue tools in the way of knocking.

                    The welding slag should not be removed

until it is cooled down. Don’t point it at the other

people while knocking on the slag incase that it will do

harm with pop-up slag.

WARNING

MAINTENANCE

   • The major difference between inverter arc welder and 

      traditional welder is the inverter welder has lots of

      advanced electronic components. What’s more, it is high

      technology product. And this requires high skill

      maintenance.
   • It is very essential to do daily maintenance. You must be

      responsible for examination and repair. Once you do not 

      have the ability to check it, kindly contact with

      manufacturer to acquire the service and support

      of technology.

The following is the steps for maintaining:

 a) Dust removal.
 b) Remove dust by professionals with dry and clean

      compressed air (using a compressor or Paper Tiger)

      regularly. Meanwhile, check inter circuit of welding

      machine regularly and make sure the cable is connected

      correctly and connectors are connected tightly. If scale

      and loose are found, please give a good polish to them.

      Then connect them again tightly. Generally, if welding

      machine is operating in environment where there is no

      heavy accumulated dust, the machine need remove dust 

      once a year. If in the environment where is polluted

      with smokes and polluted air, it is needed to be removed 

      once or even twice of each season.
 c) To maintain good contact with cable and plugs.
 d) Check up the contact conditions of cable and plug

      frequently, at least once a month for stationary use.

                    

Due to high voltage in the main circuit 

of the welder, you need to do the safety precaution

measure to prevent accidental electric shock. Don’t

open the shell except for the professionals.

Remember to turn off the power before removing

dust. And don’t meddle with the connections and

components when doing this work.

WARNING

BASIC TROUBLESHOOTING

Description

1  Abnormal indicator

2  Current knob broken
3  Motor fan can’t

    wor or low

    rotational speed

4  No open circuit

    voltage

5  Electrode holder cable

    is too hot; output

    terminals are too hot.

Bad ventilation leads to overheating protection
High environmental temperature
Exceed rated duty cycle
Potentiometer damaged
Bad power switch
Bad fan
Led broken
Overheating
Bad power switch
Capacity on electrode

holder is too small
Cable is too thin
Socket is loosen

Possible cause

Remedy

Improve ventilation conditions
Automatic recovery after decreasing
Replace potentiometer
Replace it
Replace the switch
Replace the fan
Check the circuit
See point 1
Replace the switch
Replace larger capacity electrode holder

Replace a proper cable 
Remove the oxide coat and re-tight it

Содержание KN INW-130

Страница 1: ...KN INW 130 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT...

Страница 2: ...ated protection Cautions MMA Inverter DC Arc welder is a kind of electronic product which makes its components more easily damaged While replacing or modulating the strength should not be too much in...

Страница 3: ...se from welding process Altitude must be less than 1km Keep good ventilation at a distance of 50cm around Put it in somewhere the speed of wind not less than 1m s Input Power Power supply waveform sho...

Страница 4: ...own consequences Electrode Polarity see above picture Connect the quick plug with electrode holder to the positive terminal and then tightened them up clockwise Workpiece Connection Connect the quick...

Страница 5: ...epair Once you do not have the ability to check it kindly contact with manufacturer to acquire the service and support of technology The following is the steps for maintaining a Dust removal b Remove...

Страница 6: ...e has the function of prohibit switching power supply in rapid succession within a short period of time for switching on and off The power will not open then the indicator light is not on or the fan d...

Страница 7: ...rt column 2 1 18 Radiator 4 1 19 IGBT 2 20 Radiator 1 21 Rectifier bridge 1 22 Relay 1 23 Fan 1 24 Fan net 1 25 Rear panel 1 26 Plastic plate 1 27 Ship type switch 1 28 Eletrolytic capacitor 4 D e s c...

Страница 8: ...ity must be lower than 90 If the products are still needed to continue storing after stripping repacking should be carried out according to original package s requirement Remember before storage don t...

Страница 9: ...arco a trav s de la ventana de la mascarilla No exponga ninguna parte del cuerpo al mismo tiempo a los terminales de salida positiva y negativa de soldadura sin protecci n aislada Precauciones La sold...

Страница 10: ...ento 25 C 55 C Humedad relativa del aire 40 C 50 20 C 90 El polvo cidos gases corrosivos y sustancias en el aire ambiente deben estar por debajo del nivel normal excepto los del proceso de soldadura L...

Страница 11: ...Acceda al panel posterior cable de la fuente de alimentaci n a la fuente de alimentaci n que est equipada con disyuntores y l nea de conexi n a tierra red y est estrictamente prohibido que el cable d...

Страница 12: ...o pegado Eliminaci n de escoria Despu s de terminar el trabajo debe eliminar la escoria con herramientas espec ficas para eliminar residuos PELIGRO ADVERTENCIA La escoria de soldadura no debe eliminar...

Страница 13: ...dor Contactar con el proveedor 1 Indicador anormal 2 Perilla rota 3 El ventilador del motor no funciona o la velocidad del rotaci n es baja 4 Sin voltaje de circuito abierto 5 El cable del portaelectr...

Страница 14: ...DIAGRAMA 13 Inverter welding machine130A Soldadora tipo inversora MMA TIG LIFT KN INW 130...

Страница 15: ...tes mencionados anteriormente son solo para su referencia Si hay algo diferente con la m quina real por favor considerelo como equipo original DIAGRAMA DE INTERCONEXI N Esquema del circuito del soldad...

Страница 16: ...nto debe mantenerse seco con buena circulaci n de aire y sin gas o polvo corrosivo La temperatura debe mantenerse entre 25 C y 55 C y la humedad relativa debe ser inferior al 90 Si los productos a n n...

Отзывы: