KNOVA KN HG-1500 Скачать руководство пользователя страница 5

ASSEMBLY

USE

    - when working with plastic, paint,

      varnish and similar materials, inflammable

      and poisonous gases may be produced;

      inform yourself beforehand about the

      materials to be worked on
    - take into account, that heat. may be

      transferred to combustible materials

      out of eyesight.
    - to be on the safe side, have a bucket of 

      water or a fire extinguisher handy, in

      case any material catches fire.
 • 

Prevent electrical shock.

    - never poke anything down the air

      outlet/nozzle.
    - avoid body contact with earthed

      surfaces (e.g. pipes, radiators, ranges,

      refrigerators).
    - ensure the tool does not get wet.
    - do not use the tool in damp locations.
    - when used outdoors, connect the tool

      via a fault current (FI) circuit breaker

      with a triggering current of 30 mA

      maximum, and only use an extension

      cord, which is intended for outdoor use

      and equipped with a splash proof

      coupling-socket.
 • 

Handle the cord with care

    - always keep away the cord from the

      hot air flow and the air outlet/nozzle.
    - keep the cord away from heat, oil and

      sharp edges.

    - do not carry the tool by the cord, and

      do not yank the cord to disconnect it

      from the socket.

 • On/off switch with 3 air flow settings
    

! check if switch  is in position “0”

    before plugging in

    - switch on the tool by pushing switch

      in desired position:
      1 = air flow 200-450litres/minute (50°C)
      2 = air flow 200-450 litres/minute

             (50-550°C)
      3 = air flow 450 litres/minute (50-550°C)
    - when using it for the first time, some

      smoke may emit from the tool; this is

      normal and will soon cease
    - switch off the tool by pushing switch

      in position “0”
 • Temperature setting 
    - set desired target temperature by

      pressing button 1 briefly.

    - do not suspend the tool by the cord.
 • Never use the tool in conjunction

    with chemical solvents.
 • Make sure work area is adequately 

    ventilated.
 • Keep work area clean and well lit.
 • Keep children away from work area.
 • Ensure that children do not play

    with the tool.
 • Stay alert; watch what you are doing,

    use common sense and do not operate

    the tool when you are tired.

 

 • Take a secure stance; do not overreach,

    especially on ladders and stages.
 • Ensure that the tool is switched off, 

    before putting it aside.
 • In case of electrical or mechanical

    malfunction, immediately switch off

    the tool and disconnect the plug.

AFTER USE:

 • Switch off the tool and disconnect the plug.
 • 

Allow the tool to cool down for at least

    30 minutes before storage.

 • Suspend the tool on hanging ring or set 

    it down on its rear in an upright position;

    when doing so, make sure no combustible

    materials or inflammable gases are in the

    proximity.
 • Do not store/leave the tool outdoors.
 • Store the tool in a dry and locked-up

    place, out of reach of children.

    - pressing buttons 1/2 constantly

      increases/decreases the target

      temperature, until the buttons are

      released or the maximum/minimum

      temperature is reached.
    - the target temperature applies for both

      air flow when the switch is in position

      of 2 and 3.
 • 

General use.

    - determine the right temperature by

      testing out on an inconspicuous part of

      the workpiece; start with a low

      temperature setting.
    - the temperature falls as the distance

      between the air outlet/nozzle and the 

      workpiece increases.
    - the temperature required depends on

      the material to be worked on.

Содержание KN HG-1500

Страница 1: ...KN 7402 10P Digital heat gun1 500 WATTS Pistola de calor digital KN HG 1500...

Страница 2: ...utton for increasing temp 2 Button for decreasing temp 3 LCD screen TECHNICAL DATA Power Voltage frecuency Consumption KN HG 1500 1 500 Watts 120 volts 60 Hz 12 5 A Adjustable temp Air flow volume Cor...

Страница 3: ...all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future referenc...

Страница 4: ...ple under the age of 16 years This tool is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have...

Страница 5: ...ff the tool by pushing switch in position 0 Temperature setting set desired target temperature by pressing button 1 briefly do not suspend the tool by the cord Never use the tool in conjunction with c...

Страница 6: ...lead based paint must be removed by a professional without using a heat gun Not use lead based soldering wire using the appropriate accessory simplifies the work and significantly improves the qualit...

Страница 7: ...kaging together with household waste material If the tool should fail despite the care taken in manufacturing and testing procedures repair should be carried out by an authorized service center send t...

Страница 8: ...Digital display 1 17 Cover 1 18 Rubber pad on cover 6 19 Inductor 1 20 Switch push button 1 21 Rubber pad on housing 1 22 Switch circuit board 1 23 Cable 1 24 Cable Sleeve 1 25 Screw ST4x14 1 26 Cable...

Страница 9: ...EXPLOSIVE DIAGRAM KN HG 1500 Digital heat gun1 500 WATTS Pistola de calor digital...

Страница 10: ...Bot n para aumentar temp 2 Bot n para disminu r temp 3 Pantalla LCD INFO TECNICA Potencia Voltaje frecuencia Consumo KN HG 1500 1 500 Watts 120 volts 60 Hz 12 5 A Temperatura ajust Vol de flujo de air...

Страница 11: ...orporal con superficies conectadas a tierra como tuber as radiadores estufas y refrigeradores Existe un mayor riesgo de descarga el ctrica si su cuerpo tiene contacto con tierra c No exponga las herra...

Страница 12: ...ser reparada c Desconecte la clavija de la fuente de alimentaci n antes de realizar ajustes cambiar accesorios o almacenar herramientas el ctricas Estas medidas de seguridad preventivas reducen el rie...

Страница 13: ...de un interruptor de corriente de falla FI con una corriente de activaci n de 30 mA como m ximo y s lo use un cable de extensi n que est destinado para uso en exteriores y equipado con acoplamiento so...

Страница 14: ...bre su parte posterior en posici n vertical aseg rese que la superficie est limpia y libre de polvo el aire contaminado da a al motor aseg rese que el flujo de aire sea dirigido lejos de usted asegure...

Страница 15: ...as el calentamiento de tuber as de gas es extremadamente peligroso riesgo de explosi n Secado Solamente seque con un ajuste bajo o medio de temperatura e incrementando la distancia entre la herramient...

Страница 16: ...talla digital 1 17 Cubierta 1 18 Pata de hule de cubierta 6 D e s c r i p c i n No part LISTA DE PARTES D e s c r i p c i n No part 19 Inductor 1 20 Bot n pulsador de Interruptor 1 21 Pata de hule de...

Страница 17: ...DIAGRAMA DE PARTES KN HG 1500 Digital heat gun1 500 WATTS Pistola de calor digital...

Страница 18: ...NOTES...

Страница 19: ...NOTAS...

Страница 20: ...www knova com mx...

Отзывы: