PIXEL™ Installation Instructions

1. The desk does not drive at all

Check: Is the main power connected to the control box? 

Try/Solution: Try to connect a lamp or similar to the main 
power supply to check that the supply voltage is OK. 

Check: Are all plugs mounted correctly in the control box 
and to the leg? 

Try/Solution: Check all connections. 

Check: Are there any visible damages on cables, controls, 
the control box or legs? 

Try/Solution: Contact Knoll Customer Service. 

Check: Is something blocking the movement: cables, 
furniture or other objects? 

Try/Solution: Remove items that are blocking the table.

3. The desk can only drive downward 

(Error code E01)

The desk must be initialized.

How to initialize:

Press the down button and drive to the lowest position.

Hold the button until the desk stops completely.

Reactivate the down button and hold until the desk stops 
completely.

Now the desk can drive up.

2. The desk will not drive fully upwards. Always stops in  
    the same position.

The system has set a new upwards stop position. To erase 
this position, the desk must be initialized again. See #3.