background image

 
Lastly connect the MR173 to the controller or 
controller-amp with a single cat 5 wire and RJ45 
plugs, using all 8 conductors. Plug the connector into 
keypad jack A1 or B1 (technically the MR173 can be 
connected to any keypad jack). If the cat 5 wire 
from the MR173 is plugged into A1, then the 
infrared receiver wired to room 1 on the MR173 will 
control the A1 outputs, the infrared receiver wired 
to the room 2 on the MR173 will control the A2 
outputs and the infrared receiver wired to the 
room 3 on the MR173 will control the A3 outputs.  
 
Similarly, if the cat 5 wire from the MR173 is 
plugged into B1, then the infrared receiver wired to 
room 1 on the MR173 will control the B1 outputs, 
the infrared receiver wired to the room 2 on the 
MR173 will control the B2 outputs and the infrared 
receiver wired to the room 3 on the MR173 will 
control the B3 outputs.  
If only one or two room(s) is to be controlled by 
the MR173 then the remaining two or one room(s) 
can be controlled by MR60 keypads. Be sure to 
select the room 2 or room 3 dipswitch on the rear 
of the MR60 keypad. 
 

Operation 

The infrared receiver controlled rooms cannot do 
any whole house functions except turn off the 
whole system (press off button for 5 seconds). If 
whole house functions are required a keypad will 
have to be installed. 

 
 

 

Turn This Room On   

1. Make sure MVP64 amplifier front panel power 
button is on (in) and the led color is orange or green. 

 
 Note: The RB8 remote power button is not  
         used to turn the system on.  
 

2. Momentarily push the RB8 remote input button 1-4. 
The RB8 remote input buttons correspond to the 
MR60 source button layout and the source inputs on 
the rear of the controller. After the input is initially 
selected the volume always starts at about 35%.  
3. If the sources don't turn on automatically, turn 
them on manually or with their remote control(s). 
5. Adjust the volume on the RB8 remote in this room 
only. 

Turn This Room or Whole House Off 

1. Momentarily press the RB8 remote "POWER" 
button. If this was the only room turned on, then the 
whole system will shut off. If any other room was 
turned on, only this room will shut off. 
2. To shut down the whole system at any time, press 
the RB8 remote "POWER" button for 3-5 seconds.  
3. Sources may have to be turned off manually or by 
remote. 

 

Change Sources 

Press another input source button on the RB8 remote 
control button. The RB8 remote input buttons 
correspond to the source layout of the MR60 keypads. 

 

 
Volume Up and Down 

Press the volume up or down button on the RB8 
remote. Holding the button gives continuous changes. 

 

Mute 

Momentarily press the mute button on the RB8 
remote. To restore the sound press the mute, volume 
up or down, or any source or input button and the 
source selected when the mute button was first 
pressed is restored. 
 

Room 1 Room 2 Room 3

MR173

Отзывы: