Installation Tips 

 
1. Follow all local electrical & building code requirements. 

 
2. The DIR21 is usually wall mounted at light switch height. It 

does not normally require a junction box. In order to work it 
requires a PS1202 (200 mA) or PS1205 (500 mA) 12 VDC 
unregulated power supply, IR31 (single) or IR34 (dual) emitters 

and one of the following: DIR54 (decora inwall style, 4 output), 
DIR55 (tabletop style, 4 output) or DIR58 (wall mount or SMC 

style, 8 output) connection block. 
 

3. Wires can be solid or stranded, shielded or unshielded with a 
minimum of 28 gauge for runs under 200’, 22 gauge for runs 

under 500’ and 20 gauge for runs up to 1000’. Wires can be 
looped from DIR21 to DIR21 or home run. Home runs generally 
offer more reliability and future flexibility. 

 
4. DIR21’s can be mixed and matched in larger systems with up 

to 10 DIR infrared receivers, such as the Knoll DIR10 or DIR25. 
 

5. When using a DIR connection block, connect the DIR21 
+12vdc, GND and SIG terminals to the corresponding DIR55 

terminal. Prepare the wire leads to and from the DIR receiver by 

stripping about ¼” of the insulation from each of the 3 leads. 
Twist the strands tightly together so that they do not stick out 

of the connector and cause a short circuit. Be sure to observe 
polarity. If you are connecting with the RJ45 connector you may 

need a RJ45 paralleling strip to parallel connect the wires from 
multiple DIR receivers.  

 
6. Next plug in the single or dual emitters into the DIR 
connection block.  

 
7. Then plug in the PS1202 (for up to five receivers) or PS1205 

for five to eleven receivers. 
 

8. The infrared system is usually left plugged in all the time (to 
an unswitched outlet) as it uses very little power. 

 
9. Test the digital infrared system to see if it is working 
properly. If it works only from a very close range or it does not 

work at all, first mark where the pot adjustment is on the DIR 
connection block blue color pot. This is so you can reset it to 

that starting point again. Try adjusting the pot on the 
connection block very slightly left and right as you are testing 

the receiver with the remote control. This may require two 
people. This should correct for the problem. If it still does not 

work properly, please call Knoll Systems and ask for infrared 

technical 
support at 1 

800 566 5579. 
The help line is 

normally open 
from 7:30 AM to 

5:00 PM 
Monday to 

Friday Pacific 
time. 
  

RJ45

Receiver

CD

IR31A

IR34A

DIR55

PS1202

12 V DC Power Supply

Dish

IR34A

171

   Digital

Connection

   Block

DIR21

  Digital

 Infrared

Receiver

RJ45

DIR21

  Digital

 Infrared

Receiver

RJ45

DIR21

 Digital

 Infrared

Receiver

RJ45

Note:DIR21’s are

wired in parallel

12V

GND

SIG

   DIR

Receiver

  Blue

talkback

   LED