2
These instructions should be read carefully and retained after installation by the end-user for
future reference and maintenance.
These instructions should be used to aid the installation of the following products:
SHE1BP / SHE1GP / SHE2BP / SHE2GP
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
• This product is Class I and must be earthed
• This product is IP65 rated
• Provide power to the required point of installation. Suitable IP rated junction boxes should be used where
required
• Remove the diffuser by removing the four screws using the Allen key provided (see Fig. 1)
• Mark the location of the fixing holes, and drill the holes ensuring not to infringe with any gas/water pipes or
electrical cables
• Feed the cable via the rubber grommet to retain IP rating, and secure the baseplate to the surface
• Connect the Live (brown), Neutral (blue) and Earth (green/yellow) to the terminals on the terminal block of
the LED plate, ensuring the cable is secured in the cable clamp (see Fig. 2)
SHExx
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
SHE1B / SHE1G / SHE2B / SHE2G
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for
installation
•
This product is Class I and must be earthed
•
This product is IP65 rated
INSTALLATION
•
Provide power to the required point of installation. Suitable IP rated junction boxes should be used
where required
•
Remove the diffuser by removing the four screws using the Allen key provided (see Fig. 1)
Remove screws
Fig. 1
•
Remove the fastening screws securing the LED plate and lift out
•
Mark the location of the fixing holes and drill the holes ensuring not to infringe with any gas / water
pipes or electrical cables
•
Feed the cable via the rubber grommet to retain IP rating and secure the baseplate to the surface
•
Connect the Live (brown), Neutral (blue) and Earth (green/yellow) to the terminals on the terminal
block ensuring the cable is secured in the cable clamp (see Fig. 2)
Fig. 2
•
Ensure the earth lead on the LED plate is secured correctly to the earth lead on the body of the
fitting
•
Refasten the LED plate screws
•
Choose the required colour temperature by means of the DIP switch (see Fig. 3)
Fig. 1