background image

These instructions should be read carefully and retained after installation by the end user for future 
reference and maintenance.
These instructions should be used to aid installation of the following products: 
LANT3 / LANT3W / LANT4 / LANT4W

GENERAL INSTRUCTIONS

SAFETY

INSTALLATION

•  Installation of this luminaire should only be carried out by a qualified electrician or competent 

person to the latest Building and current IEE Wiring Regulations (BS7671)

• Please isolate mains prior to installation/maintenance
•  Check the total load on the circuit (including when this luminaire is fitted) does not exceed the 

rating of the circuit cable, fuse or circuit breaker

•  Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for 

installation

• This product is Class II double insulated
• This product is non-dimmable 
• This product is IP54 rated

•  Provide power to the required point of installation. Suitable IP rated junctions boxes should be used 

where required

• Remove the 2 screws on the front of the luminaire (see Fig 1)

•  Using the baseplate as a template, mark the location of the 

fixing holes, and drill the holes ensuring not to infringe with 
any joists, gas or water pipes or electrical cables

•  Feed the mains cable through the rubber grommet to retain 

the IP rating and secure the baseplate to the desired surface 
Connect Live (brown) and Neutral (blue) to the 2-way 
terminal block (see Fig 2)

Fig 1

Remove screws 

from these locations