These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
FLP100 / FLP100A / FLP150 / FLP150A / FLP200 / FLP200A
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, please consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
• This product is Class I and must be earthed
• This product is IP65 rated
Note
- If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable
IP rated junction boxes should be used where required
• Round cable should be used for the mains supply. The use of flat cable will cause water ingress to the fitting
• Remove the four screws on the access plate at the rear of the fitting to expose the terminal block
(see Fig. 1)
Screws
Fig. 1
FLPXX
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
FLP100 / FLP150 / FLP200
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, please consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for
installation
•
This product is Class II double insulated
•
This product is IP65 rated
INSTALLATION
Note - If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
Remove the four screws on the access plate at the rear of the fitting to expose the terminal block (see
Fig. 1)
Fig.1
•
Feed the cable through the compression gland on the rear of the access plate. Ensuring correct polarity
is observed, carefully wire as shown in Fig. 2
Fig. 2
•
Replace the access plate and screws ensuring gasket is in place then tighten the compression gland
ensuring a tight seal to maintain the IP rating
•
Switch on and check for correct operation