Change dispenser ID # 

Change main access code 

Set date and time 

Set unit of measure 

Set flush time and sampling delay 

Set simultaneous pump operation 

Set number of users 

***       DISPENSER       *** 

SETUP ROUTINES 

This menu selection allows you to change the dispenser ID 
number. The dispenser ID number has two purposes: 

(1) It is printed in the upper-left corner of reports to identify which 
dispenser the report came from. This can be helpful when more 
than one dispenser is installed at the location. 

(2) When running ILCS WinReporter software (optional), the ID 
number is used for “logging on” to the dispenser from the 
computer. Several dispensers can be connected together in a 
daisy chain format known as “multilinking”. 

Press YES to invoke the command, or press NO to move on to 
the next menu selection. If the ID number is changed, you must 
set the ID of the external memory module in menu #1. 

CHANGE DISPENSER ID# ? 

PRESS: YES OR NO 

NO 

YES 

GO TO NEXT PAGE 

Use the number buttons to enter a 2-digit ID number, 
then press ENTER. Press the MENU 

 button to move 

on to the next menu selection. 

NEW DISPENSER ID# 00 

THEN PRESS ENTER 

This menu selection allows you to change the main access code. 
Press YES to invoke the command, or press NO to move on to 
the next menu selection. 

CHANGE MAIN ACCESS CODE ? 

PRESS: YES OR NO 

NO 

YES 

Use the number buttons to enter a 3-digit main access 
code, then press ENTER. Press the MENU 

 button to 

move on to the next menu selection. 

MAIN ACCESS CODE = 000 

THEN PRESS ENTER 

This menu selection allows you to set the time and date. Press 
YES to invoke the command, or press NO to move on to the next 
menu selection. 

SET DATE & TIME ? 
PRESS: YES OR NO 

NO 

YES 

Use number buttons to set date and time (military format, 
13:00 = 1:00 PM) then press ENTER. Press the MENU 

 button to move on to the next menu selection. 

HOUR 00                          MINUTE 00 
MONTH 00         DAY 00          YR 00 

Содержание ILCS

Страница 1: ...0900511 Rev E 06 05 Page 1 of 20 ILCS Version 2 1 System Programming Manual ...

Страница 2: ...s 16 Operation 18 Warranty Information 20 Knight Locations 20 CAUTION Wear protective clothing and eyewear when dispensing chemicals or other materials Observe safety handling instructions MSDS of chemical mfrs CAUTION To avoid severe or fatal shock always disconnect main power when servicing the unit CAUTION When installing any equipment ensure that all national and local safety electrical and pl...

Страница 3: ...on Set number of users Change user access code Change user password Change formula access Change report name Change chemical names and costs Change formula names Set shift times Set operating zone Date dispenser installed Date squeeze tube last changed Date squeeze tube last lubed Prime pumps Calibrate pumps Manually enter pump flow rates Program formulas DISPENSER MEMORY FUNCTIONS 1 DISPENSER SET...

Страница 4: ...0900511 Rev E 06 05 CYCLE START BUTTON PROGRAMMING DISPLAY MAIN POWER ON OFF SWITCH WATER FLUSH PUSH BUTTON ALPHANUMERIC KEYPAD PROGRAMMING KEYPAD ILCSCONTROLLERDIAGRAM CYCLE ON OFF KEYSWITCH FORMULA NUMBER DISPLAY ...

Страница 5: ...formation TOPROGRAMDISPENSERPRESS ENTER IMPORTANTNOTES Leading zeroes on main access code user access code and user passwords are not required to be entered For example a user password of 010 can be typed in as 10 then press ENTER Its recommended to clear pump volumes sum cycle report and batch count then loading factory defaults prior to initial programming of formulas See MEMORY FUNCTIONS menu 1...

Страница 6: ... menu selection without clearing This message indicates that the clearing process is active When the process is complete the next menu item will appear CLEARING ALL PUMP VOLUMES This menu selection is used to clear the summary and cycle report memory also known as the batch tracking report Press YES to begin clearing or press NO to move on to the next menu selection without clearing NOTE This will...

Страница 7: ...ithout loading factory defaults LOAD FACTORY DEFAULTS PRESS YES OR NO NO YES You are then asked if you really do want to use this command Press YES if you are sure or press NO to move on to the next menu selection without loading This message indicates that the clearing process is active factory defaults are being loaded at this point When the process is complete the next menu item will appear CLE...

Страница 8: ...he process is complete you will be returned back to the menu heading SETTING EXT MEM MODULE ID TO CURRENT ID ARE YOU SURE PRESS YES OR NO YES NO This menu selection allows you to clear all time stamp data from the external memory module Press YES for a new installation or if you wish to clear old data from the memory module that is no longer needed Press NO if you do not wish to clear the memory m...

Страница 9: ...r is changed you must set the ID of the external memory module in menu 1 CHANGE DISPENSER ID PRESS YES OR NO NO YES GO TO NEXT PAGE Use the number buttons to enter a 2 digit ID number then press ENTER Press the MENU button to move on to the next menu selection NEW DISPENSER ID 00 THEN PRESS ENTER This menu selection allows you to change the main access code Press YES to invoke the command or press...

Страница 10: ...right lowest number to highest Use the number buttons to make your selection Press the MENU button to continue SIMULTANEOUS PUMPS OFF 1 OFF 2 ON Disregard this menu for systems without flush manifold This menu selection allows you to set the amount of time that the optional flow sensor switch can break contact before giving a flush error Use the number buttons to set the sampling time and then pre...

Страница 11: ...the MENU button to move on to the next menu selection USER ACCESS CODE 000 THEN PRESS ENTER This menu selection allows you to change user passwords Press YES to invoke the command or press NO to move on to the next menu selection CHANGE USER PASSWORD PRESS YES OR NO NO YES Use the SCROLL buttons and alphanumeric keypad to enter a 3 digit password and descriptive name up to 15 characters for the us...

Страница 12: ...O VIEW Type in the user ID number and press ENTER The screen will display current settings for each formula Use MENU or to choose other formula numbers Press RESET when finished and you will be returned to the previous screen 001 FORM 01 02 03 04 USERID NAME 1 1 1 1 TO CHANGE Type in the user number and press ENTER Then use the SCROLL buttons to move to the cursor below the formula you wish to cha...

Страница 13: ... selection This menu selection allows you to change the chemical names Press YES to invoke the command or press NO to move on to the next menu selection CHANGE CHEMICAL NAMES PRESS YES OR NO NO YES Choose pump number and press ENTER Move cursor SCROLL to set the product name and press ENTER Repeat for all pumps Press MENU when finished PUMP 01 PUMP 01 This menu selection allows you to change the p...

Страница 14: ...enu selection WANT TO SET SHIFT TIMES PRESS YES OR NO NO YES Use the number buttons to enter the shift start times then press ENTER Time must be in military format i e 13 00 1 00 PM Press the MENU button to move on to the next menu selection START TIMES 1 06 00 2 11 00 3 17 00 This menu selection allows you to set the operating zone The operating zone is the time range in which formulas can be acc...

Страница 15: ...on allows you to set the date that the squeeze tubes were last changed Use the number buttons to set the date then press ENTER Do this for each pump in the system Press the MENU button to move on to the next menu selection SQUEEZE TUBES CHANGED PUMP 01 00 00 00 This menu selection allows you to set the date that the squeeze tubes were last lubed Use the number buttons to set the date then press EN...

Страница 16: ...s to be valid CALIBRATE PUMPS PRESS YES OR NO NO YES If you know the exact flow rate of the pump you can choose to manually enter the value instead of calibrating however it is recommended to calibrate each pump as flow rates can vary due to chemical viscosity Press YES to invoke the command or press NO to move on to the next menu selection Choose the pump number and press ENTER while the blinking...

Страница 17: ...R CALIBRATION VOL PUMPED 000 0 OZS Press YES to repeat the calibration process for another pump Be sure to calibrate all pumps in the system including pump 9 if using water in the formula programming If all pumps have been calibrated press NO to continue on to the next step CALIBRATE ANOTHER Y N P 01 000 0 OZ NO YES This selection is used to input up to 99 formulas A formula can consist of one or ...

Страница 18: ... pumps are finished the flush will activate for its programmed time and the 3 way valve if used will activate after the time set to drain after If the RESET button is pressed during operation you will then see the following message The top line will show the current formula name The bottom line will alternate between the date time and the display shown to the left Use to choose the desired formula...

Страница 19: ...0900511 Rev E 06 05 Page 19 of 20 NOTES ...

Страница 20: ... Return Authorization KRA number freight prepaid and found to be defective upon factory authorized inspection Bearings and pump seals or rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equip...

Отзывы: