background image

Page 13

Assembly Instructions

knightgroup.co.nz

Agile Pro 

Electric 3 Column Double Sided Desk

Initial Setup Procedure & Manual Reset

NOTICE

Operating the desk system when it is not properly connected can damage the product.

• 

Ensure all Cables are properly connected

• 

Ensure that all required Actuators are ready to be operated

• 

Do not operate the Desk System until it is properly connected

• 

The Manual Reset Procedure is used to align the position of the Actuators within the desk system.    
You must perform a Manual Reset Procedure before using the whole system for the first time.

 

Risk of minor or moderate injury through crushing.

Anti-Collision system is inactive during start-up and reset processes. This may lead to minor or moderate
injury through crushing. Ensure that no persons or objects are in the desk’s range of motion.

rES

1.

Keep pressing DOWN key till the handset display shows “E-1” and “rES”
alternately and release the key.

60

2.

Keep pressing DOWN key, the desktop will move slowly down and return back
till the display shows “060”.

3.

Release the DOWN key.
> Now the electric height-adjustable desk can be used normally.

 

Содержание Agile Pro

Страница 1: ...knightgroup co nz Assembly Instructions Tools Required Powered Screwdriver Tape Measure Agile Pro Electric 3 Column Double Sided Desk Foldout Leg ...

Страница 2: ......

Страница 3: ...tion or power off The height adjustable table is designed for use in dry work environments only The table height is infinitely adjustable within its height range so that it can be set to the user s most ergonomic working height The user should seek professional help to establish their optimum working height The table has been designed as a devise to elevate the users work surface and associated of...

Страница 4: ...3 Cable Tray 1 4 M8 18 Counter Sunk Head Screw 8 5 Side Rail 2 6 M6 10 Screw 36 7 Adjustable Frame 2 Part Name Qty PCS 8 ST4 8 16 Tapping Screw 22 9 ST3 5 16 Tapping Screw 8 10 Control Box 2 11 Handset 2 12 Power Cord 2 13 Extension Cable 4 14 Cable Clip 8 12 13 14 11 10 9 8 7 M M 12 12 3 3 Two People Tools Assembly Time 20 min 5 1 2 4 3 6 ...

Страница 5: ...sists of two identical single sided desk systems Take out one side frame and set the frame flat Unfold the left and right column respectively Line up the screw holes on the frame and columns Install the frame screws The installation method on the other side frame is the same Unfold when laying down Avoid damaging the motor cables Motor Cable M6 10 Screw ...

Страница 6: ...n Double Sided Desk Step 2 Place the side brackets onto the frame Install the bracket screws and fasten the frames pre installed screws The installation method on the other side frame is the same Avoid excessive tightening of screws Fasten the screws M6 10 Screw M6 10 Screw ...

Страница 7: ...ments are followed when setting the column spacing and fasten the frame screws The installation method on the other side frame is the same Avoid excessive tightening of screws Both sides of the desk must be adjusted to the same width The frame width is adjustable 1100 1800mm which is suitable for different desktops 980mm 1200 Worktop 1260mm 1500 Worktop 1360mm 1600 Worktop 1560mm 1800 Worktop Fast...

Страница 8: ...ne side to the columns and fasten the screws and then install the other side rail on the other side in the same way Avoid excessive tightening of screws Agile Pro Electric 3 Column Double Sided Desk M8 18 Counter Sunk Head Screw M8 18 Counter Sunk Head Screw M6 10 Screw M6 10 Screw ...

Страница 9: ...Turn the frame upright Take out the cable tray and remove the cover Insert the cable tray into the side rails and fasten the screws Avoid excessive tightening of screws Agile Pro Electric 3 Column Double Sided Desk M6 10 Screw Fasten the screws M6 10 Screw ...

Страница 10: ... fix chosen screens brackets purchased separately to the side rails and fasten the screws Place cable tray cover on top of cable tray Avoid excessive tightening of screws Related screws and screen brackets together Agile Pro Electric 3 Column Double Sided Desk M6 10 Screw ...

Страница 11: ...knightgroup co nz Step 7 Install screen purchased separately with screen brackets and fasten the screws Avoid excessive tightening of screws Related screws and screen brackets together Agile Pro Electric 3 Column Double Sided Desk ...

Страница 12: ... that the screen should be 20mm from the edge of the desktop and fasten screws Install handset in a suitable position underneath desktop edge to avoid interference with humans or chairs display screen facing out and fasten screws Avoid excessive tightening of screws Agile Pro Electric 3 Column Double Sided Desk ST3 5 16 Tapping Screw ST4 8 16 Tapping Screw ...

Страница 13: ...Page 11 Assembly Instructions knightgroup co nz Step 9 Install control boxes on the frame see below diagram Control Box Handset Agile Pro Electric 3 Column Double Sided Desk ...

Страница 14: ...n in the below connect related parts including control box handset extension cable and power cord etc and fasten with cable clips Agile Pro Electric 3 Column Double Sided Desk Cables are for illustrative purposes only Do not attach cables until assembly is complete ...

Страница 15: ...rs within the desk system You must perform a Manual Reset Procedure before using the whole system for the first time Risk of minor or moderate injury through crushing Anti Collision system is inactive during start up and reset processes This may lead to minor or moderate injury through crushing Ensure that no persons or objects are in the desk s range of motion rES 1 Keep pressing DOWN key till th...

Страница 16: ...n reached To move the Table Top DOWN Press and hold the DOWN Key until the required height has been reached Saving a Memory Position This function saves a set desktop position One Memory Position can be saved per Memory Position Key 1 Move the desk to the required height 2 Keep pressing the M Key till the display will show S 3 Press 1 key the display shows current height and S alternately 4 Press ...

Страница 17: ...y the display will show alternately L P and current height keep pressing DOWN key till the low limit position is reached press M key the low limit position has been set NOTICE Do not enable this function only when you are really need in some situation Changing the displayed desktop height unit This function will be used to change the height display unit After setting the handset will display the h...

Страница 18: ...he unit is mm during this procedure 4 Press M key the height has been changed to defined digit INFO During the adjustment procedure every time you press the 1 2 or 3 key the corresponding number will increase by 1 Reset to Factory Setting With this function you can make the control system to factory setting including memory position High and Low limit position height displayed etc 1 Keep pressing ...

Страница 19: ...ight Difference After moving the height between the two columns exceeds 1 inch stop any operation and execute the Manual Reset procedure ovr Overloading Remove the load on desktop till it less than 1400N 315 LBS for further operation dut Operated continuously without suitable rest Make the desk rest around 18minutes for further operation The display will show alternately as dut and a countdown num...

Страница 20: ...knightgroup co nz ...