Page 8
Assembly Instructions
knightgroup.co.nz
Page 8
Assembly Instructions
Digital Handset
Agile Boost Desk
The whole handset surface is a button panel. If there is no press
within 30 seconds, the screen is locked and 1/2/3/4/S keys are locked
correspondingly, press the Up or Down buttons first, handset can
then be used when the display screen lights up.
OPERATION
• Display screen
- Shows current height of desk
• Up & down button
- Push and hold button to adjust desk height
until you reach optimum height.
• Memory button
- After setting the memory desk height, desk will
auto adjust to the chosen setting.
• How to set memory buttons
- Click the “S” key when running to a
specific point. The display screen displays “S-” and “-” flashes. At this
time, press “1-4” button to store the position to the corresponding
label, the memory height is successfully saved. Press 1/2/3/4, the
desk will move to the saved memory height automatically.
• Set button (S)
- Press the “S” key when memory and internal
parameters need to be set.
INITIALIZATION
1.
When “RST” is on the display screen, press the “DOWN” button
until the desk frame reaches its lowest point. After hearing the
“di” sound and desk frame rebounds, initialization is completed.
(P.S. The button cannot be released during this operation,
otherwise the initialization will fail).
2.
Forced initialization: Press the “DOWN” button until the desk
frame reaches its lowest point, then release the button and press
it again for about 5 seconds until hear the “di” sound and desk
frame rebound, and the initialization is completed.
3.
Restore the factory settings: When controller is changed or the
parameters need to be restored to the factory settings, press the
“DOWN” and “Up” buttons simultaneously, you will hear the first
“di” sound after about 5 seconds and second “di” sound after 10
seconds. When the display screen shows “RST”, please operate
refer to Step 1 above.
SAFETY FUNCTION
When the desktop is on the rise or down, encountered reverse
resistance,the desk will rebound.
ERROR CODES
E1, E6, E7 = Power fault
Change power.
E2 = Synchronous height over 1cm
Implement the initialization Step 1.
E4 = Handset fault
Unplug and replug the cable of handset.
E5 = Anti-collision alert
Rebound reminder, normal condition.
E8 = Desktop sloping
Check the desktop.
E11, E21 = Motor defect
Inspect the motor wire.
E12, E22 = Controller fault
Exchange the controller.
E14~E17, E24~E27 = Motor fault
Change motor.
E18, E28 = Overload protection
There is too much weight on desk. Lighten load, power off and restart.
HOT = Overtime power protection
Automatic recovery, stop using for 20 minutes.
Display
Screen
Memory
Buttons
Set
Button
Up & down
Buttons