![KNF NPK012 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/knf/npk012-series/npk012-series_operating-and-installation-instructions_1980076015.webp)
Swing Piston vacuum pump NPK012
Installation and connection
Translation of original operating and installation instruction, Englisch, KNF 316780-316783 05/19
15
Connection diagram for motor controller
Motor
Rated voltage
[V]
24
Voltage range
[V]
9 – 26.4
Electrical connections
Leads connections
Function
Wire lead color Signal name
Size
+ Supply voltage
Red
U
+
AWG 26 / UL 3266
- Supply voltage (0 V)
Black
U
-
/ GND
AWG 26 / UL 3266
Input signal for speed control
Blue
U
Ctrl
AWG 26 / UL 3266
Output signal for speed
Green
U
Spd
AWG 26 / UL 3266
Input signal for remote ON/OFF
White
U
Rmt
AWG 26 / UL 3266
Input signal for direction of motor rotation
Yellow
U
Rot
AWG 26 / UL 3266
Input signal for speed control UCtrl
PWM frequency range
[kHz]
20
[10 … 30]
Input level "high"
[V]
5
[2.5…5.5]
Input level "low"
[V]
0
[0…0.8]
Duty cycle range
[%]
PR
VA
30… 0
50…0
Pulse duration description:
Min. → min. pump output
Max. → max. pump output
[%]
PR
VA
30
0
50
0
Input impedance @ 1 kHz
[kΩ]
≥ 10
Output signal for speed USpd
Pulses per revolution
[-]
6
Pulse duty cycle
[%]
50
Output level "high"
[V]
5
[2.5…6.0]
Output level "low"
[V]
0
[0…0.8]
Max. current carrying capacity
[mA]
2
Input impedance @ 1 kHz
[kΩ]
≥ 10
Input signal for remote ON/OFF URmt
Input level "high" → Motor ON
[V]
5
[2.5…5.5 or open contact]
Input level "low" → Motor OFF
[V]
0
[0…0.8]
Input impedance @ 1 kHz
[kΩ]
≥ 10
Input signal for direction of motor rotation URot
Standard for pump
Input level "high" → Motor CCW
[V]
5
[2.5…5.5 or open contact]
Not recommended for pump
Input level "low" → Motor CW
[V]
0
[0…0.8]
Input impedance @ 1 kHz
[kΩ]
≥ 10
Tab. 9 Connection diagram for motor controller NPK 012_DC-B-M