Diaphragm Pumps NMP830 HP
Technical data
KNF Micro BA317001-316999 NMP830_HP-EN 0221.docx
Translation of original Operating and Installation Instructions, English
7
Characteristics NMP830KPDC HP
Motor specification
Supply voltage[V]
5)
12
24
Max. current consumption [A]
0.9
0.5
Connection [-]
Flat plug A 2.8x0.5
DIN46244
Protection class [-]
IP 20
Weight
1)
[g] / [oz]
185 / 6.53
Flow rate [l/min]
2), 3)
5
Max. operating pressure [bar g] / [psi g]
2), 3)
3 / 43.5
Max. vacuum [mbar abs] / [inHg]
2), 3)
230 / 6.8
Tab. 4
Characteristics NMP830KPDC-B HP (brushless)
B: Brushless motor with internal electronic
– 2 wires
Motor Variants
Supply voltage[V]
5)
12
24
Max. current consumption [A]
0.85
0.45
Connection [-]
Wires AWG24
Protection class [-]
IP 54
Weight
1)
[g] / [oz]
170 / 6
Flow rate [l/min]
2), 3)
5
Max. operating pressure [bar g] / [psi g]
2), 3)
3.0 / 43.5
Max. vacuum [mbar abs] / [inHg]
2), 3)
230 / 6.8
Tab. 5
Characteristics NMP830KPDC-B4 (brushless)
B4: Brushless motor with internal electronic - 4 wires
Motor Variants
Supply voltage[V]
5)
12
24
Max. current consumption [A]
0.85
0.45
Connection [-]
Wires AWG24
Protection class [-]
IP 54
Weight
1)
[g] / [oz]
170 / 6
Flow rate [l/min]
2), 3), 4)
5
Max. operating pressure [bar g] / [psi g]
2), 3), 4)
3.0 / 43.5
Max. vacuum [mbar abs] / [inHg]
2), 3), 4)
230 / 6.8
Tab. 6
1)
The weight may differ slightly from the stated value, depending on the version.
2
)
Depending on the application level (MASL), ambient temperature, material design
of the pump head and the connection hoses used, the flow rates may vary from the
values shown.
3)
Measured with air at 20°C / 68°F at atmospheric pressure
4)
at 5V control voltage
5)