Diaphragm Pump N1200.12, N1400.1.2.12
Installation and connection
Translation of Original operating and installation instruction, English, KNF 308930-308933 02/22
23
6.5 Connecting water cooling (optional)
) can increase the service life
of the diaphragm, particularly with high pressures or high ambient
temperature.
Operating parameters
Parameter
Value
Water temperature [°C]
+ 5 to + 30
Water pressure [bar gauge]
< 1.0
Water flow rate [l/min]
> 1.0
Tab.14 Recommended parameters for connecting the water cooling
1. Connect the water cooling system to the provided hose connections.
à
Safely drain the water discharge.
The flow direction is allowed in both directions.
Mounting dimensions For mounting dimensions, see the following dimensional drawings:
The base plate is shown as an additional accessory on the following
dimensional drawings.
Fig.9 Mounting dimensions pump series N1200.12