Diaphragm pump N922 EX
Technical data
Translation of Original Operation and Installation Instruction, english, KNF 313600 11/19
13
4 Technical data
4.1 Technical data
Pump materials
Assembly
Material
Pump head
Modified PTFE
Diaphragm
PTFE-coated
Valve plate/seal
FFPM
O-ring (only .29 versions)
FFPM
Tab. 17
Pneumatic values
Parameter
Value
N922 EX 16L
Value
N922 EX 8L
Max. permissible operat-
ing pressure [bar rel]
1.0
1.5
Ultimate vacuum [mbar
abs.]
≤200
≤350
Flow rate at atm. pres-
sure [l/min]*:
-open bypass
-closed bypass
50 Hz
60 Hz
50 Hz
60 Hz
10 ± 10%
16 ± 10%
12 ± 10%
18 ± 10%
3 ± 15%
7.5 ± 10%
4 ± 15%
9 ± 10%
Flow rate at max. permis-
sible operating pressure
[l/min]*
6.5 ± 10% 8 ± 10%
0
0
Tab. 19 *Liters in standard state (1013 mbar)
Other parameters
Parameter
Value
Permissible ambient temperature
[°C]
+ 5 to + 50
Permissible media temperature [°C] + 5 to + 50
Dimensions
N922 EX (three-phase motor)
N922 EX (capacitor motor)
N922.29 EX (three-phase motor)
N922.29 EX (capacitor motor)
See Fig. 4, Kapitel
See Fig. 3, Kapitel
See Fig. 6, Kapitel
See Fig. 5, Chapter
Electrical data
See motor type plate
Gas tightness* of the pump head
< 6 x 10
-3
mbar l/s
Relative air humidity
80% for temperatures to 31°C, de-
creasing linearly to 50% at 40°C
Starts against:
- Vacuum
- Pressure
0.5 bar g
800 mbar abs.
Tab. 21 * The gas tightness of the pump head is no longer ensured after the pump
head is opened or after replacing diaphragm and valve plates/seals. A leak test