Installation and connection
Translation of original Operating and Installation Instructions, english, KNF 308934-308937 09/18
23
7.4. Connecting the water cooling system
(optional)
Water cooling (see 11.2 Accessory) can increase the service
life of the diaphragm, especially at high pressures or high am-
bient temperatures.
Recommended parameters
Parameter
Value
Water temperature
+ 5°C to + 30°C
Water flow quantity [l/min]
1.0
Tab. 12
Mounting dimensions see Fig. 8 and Fig. 9.
The base plate is shown as an additional accessory in the fol-
lowing dimension drawings.
Fig. 8: Mounting dimensions pump series N 2400.15 SPE (All dimensional
tolerances conform to DIN ISO 2768-1, Tolerance Class V)
Mounting dimensions