Diaphragm Pump N 035 E
Design and Function
KNF N 035 E e 08/09 Translation of the original Operating and installation instructions
11
Function diaphragm pump
1
Outlet
valve
2
Inlet
valve
3
Transfer
chamber
4
Diaphragm
5
Eccentric
6
Connecting rod
7
Pump
drive
Fig. 4: Pump head
The pump transfers, compresses (depending on pump version)
and evacuates gases and vapors.
The elastic diaphragm (
4
) is moved up and down by the eccentric
(
5
) and the connecting rod (
6
). In the downward stroke it aspirates
the gas to be transferred via the inlet valve (
2
). In the upward
stroke, the diaphragm presses the medium out of the pump head
via the outlet valve (
1
). The transfer chamber (
3
) is hermetically
separated from the pump drive (
7
) by the diaphragm.