Safety

The freshness cooler is all around glazed 

and is delivered fully assembled (ready 

to plug in). Apart from the correct align-

ment at the installation site, final assemb

-

ly by the user is not required.

The person responsible on site 

(e.g. the store manager in the 

case of installation in a super-

market) must ensure that the 

operators of the freshness 

cooler at the installation site are instruc-

ted in the correct use of the present 

operating manual and are familiar with 

it.

The freshness cooler meets all the re-

quirements of EU Directive 2011/65EU 

(RoHS2) on the avoidance of hazardous 

substances in electrical and electronic 

equipment and EU Directive 1907/2006 

(REACH) on the registration, evaluation 

and approval of chemicals. The refrige-

ration system installed in the cooler works 

with the refrigerant R290 (propane) and 

the insulating foam polystyrene.

•  The global warming potential (GWP) 

corresponds to the value 3 and the 

ozone depletion potential (ODP) to 

the value 0.

Technical data and filling 

quantities can be found on 

the type plate of the cooler 

and on the product data 

sheet, which you can obtain 

from KMW customer service.

Only use the freshness cooler as descri

-

bed in this user manual. Any other use 

is considered improper and can lead 

to property damage or even personal 

injury.

The freshness cooler is not a child‘s toy. 

The manufacturer assumes no liability for 

any injury, loss or damage resulting from 

improper or improper use. Possible exam-

ples of improper or incorrect use are:

•  Use of the freshness cooler for pur-

poses other than those for which it is 

intended

• 

Non-observance of the safety inst

-

ructions and warnings, as well as the 

assembly, operation, maintenance 

and cleaning instructions contained 

in this operating manual

• 

Non-observance of any accident 

prevention regulations specific to the 

use of the cooler and/or generally 

applicable

•  Use of accessories and spare parts 

that are not intended for the fresh-

ness cooler

•  Changes to the freshness cooler
• 

Repair of the freshness cooler by so

-

meone other than the manufacturer 

or a specialist

•  Operation or maintenance of the 

freshness cooler by persons who are 

not familiar with the handling of the 

freshness cooler and/or do not un-

derstand the dangers involved.

Содержание Usedom

Страница 1: ...Operating Manual Refrigerated display cabinet Usedom Commercial refrigerated cabinet ...

Страница 2: ...defrost running cooling is running fans are running 2 ...

Страница 3: ...el load limit line impact protection light switch LED optional air intake grille thermostat controller button forward back program keys display icons temperature display substructure adjustable feet with thread M10 temperature display weighted air inlet and air outlet temperature 3 ...

Страница 4: ... disconnect the refrigeration island from the power supply 12 Cleaning 13 Do not clean with 13 Defrost 13 Defrosting of devices without bus connection 13 Defrosting of devices with bus connection 13 Maintenance 14 Risk of injury 14 Risk of circuit 14 Decommissioning transport and storage 15 Productdetails and functionality 15 Climate class 15 Cooling unit 15 Housing and cooling storage 15 Temperat...

Страница 5: ...pecific guidelines and laws abroad Keep this operating instruction for further use If you pass the cooler on to third parties be sure to include these opera ting instructions 5 Explantion of symbols The following symbols and signal words are used in this user manual on the freshness cooler or on the packaging This signal symbol word indicates a hazard with a high level of risk which if not avoided...

Страница 6: ... surfa ces Caution danger of explosion Entering the surface prohibited Read the user manual Intended use The freshness cooler is a commercial refrigeration unit It is designed as sales furniture for packaged food in tempera ture class M1 in the self service area The freshness cooler is not suitable for use on board ships or aircrafts It must be ensured that the set and rea ched temperature inside ...

Страница 7: ...e found on the type plate of the cooler and on the product data sheet which you can obtain from KMW customer service Only use the freshness cooler as descri bed in this user manual Any other use is considered improper and can lead to property damage or even personal injury The freshness cooler is not a child s toy The manufacturer assumes no liability for any injury loss or damage resulting from i...

Страница 8: ...facturer Electric shock hazard Faulty electrical installation or excessive mains voltage can lead to electric shock Safety instructions for the authorized spe zialist Only connect the freshness cooler if the mains voltage and mains fre quency of the socket correspond to the information on the rating plate Only connect the cooler to an easily accessible socket so that you can quickly disconnect the...

Страница 9: ...tments to the tempera ture controller to be carried out by authorized specialists To do this con tact KMW customer service Safety instructions for the authorized spe zialist Only parts that correspond to the original device data may be used for repairs This cooler contains electrical and mechanical parts that are essential to protect against sources of danger Do not operate the freshness cooler wi...

Страница 10: ...commit to repair minor damage to the freshness ooler that does not impair any technical functions e g dents in the housing cau sed by shopping trolleys If there is damage to the refrigeration system or the electrics the KMW custo mer service must be informed immedia tely Otherwise there is a considerable risk of injury In case of improper handling or use the re is a risk of damaging the cooler and...

Страница 11: ... cooler in a single or row installation a minimum distance of 50mm to all four boun dary surfaces such as walls other devices shelves etc must be main tained The installation location should not be exposed to excessive drafts or large heat sources This can impair the per formance of the freshness cooler In the case of block or row configura tions these must be ordered in ad vance to match Other in...

Страница 12: ...ommends using a cable duct on the floor with sockets built into it or mounted on it to connect the cooler Electric circuit protection Before connecting the freshness cooler to an electrical circuit you must ensure that the corresponding electrical circuit is correctly secured Miniature circuit breakers LS switches for protection against overcurrent and residual current circuit breakers FI switches...

Страница 13: ...start time of the automatic defrosting process is preset at the facto ry In exceptional cases it may be ne cessary to defrost the cooler manually e g due to a fault improper installation overloading after cleaning or due to other sources of interference The way you do this depends on whether your freshness cooler is connected to a wurm system or not Defrosting devices without a bus con nection Dis...

Страница 14: ...r scrape off any existing lay er of ice or frost with pointed objects or tools This could damage the evapora tor Risk of injury In the event of improper handling or use there is a risk of injury from rotating fans and sharp edges When cleaning below the floor display the mains plug must be pulled out befo re cleaning Always use suitable protective gloves when cleaning the freshness cooler to avoid...

Страница 15: ... pro per handling of the freshness cooler Climate class Cooling devices must always correspond to one of the climate classes 0 to 8 ac cording to the ISO 23953 2 standard The climate class specifies specifications for the environment in which the device is operated The cooler is designed as a device in climate class 3 for which a maximum ambient temperature of 25 C and a maximum relative humidity ...

Страница 16: ... defrosts automatically at re gular intervals It is usually not necessary to defrost the cooler manually To do this observe the procedure in the chapters on cleaning and maintenance Temperature controller refrigeration controller With the help of the temperature cont roller the temperature in the goods area is regulated to an adjustable setpoint The temperature controller is set electro nically Al...

Страница 17: ...dentally stored that were too warm Did you previously have a longer power outage Contact KMW customer service if the fault is not due to any of the causes listed here When contacting KMW Cus tomer Service always give the serial number of the cooler and the type of fault or a de scription of the malfunction In any case contact KMW customer service if loud noises and or strong vibrations occur on th...

Страница 18: ...ions 1395x1100x980mm Internal dimensi ons 1270x700mm Glass display 1 1250x340mm Display area 1 62m Weight 215kg 18 Disposal Dispose of packaging Discard the packaging unmixed Give cardboard to the waste paper foils to the recyclables collection Dispose the freshness cooler Applicable in the European Union and other European countries with systems for separate collection of recyclables Old devices ...

Страница 19: ...nized standards for Machinery Directive 2006 42 EG DIN EN 60335 1 2020 08 VDE 0700 1 2020 08 DIN EN 60335 289 2018 10 VDE 0700 89 2018 10 DIN EN 62233 2008 11 VDE 0700 366 2008 11 DIN EN 62233 Correction 1 2009 04 VDE 0700 366 correction 1 2009 04 DIN EN ISO 12100 2011 03 Applied harmonized standards for EMC directive 2014 30 EU DIN EN IEC 61000 3 2 2019 12 VDE 0838 2 2019 12 DIN EN 61000 3 3 2020...

Страница 20: ...g GmbH is inadmissible and punishable This applies in particular to reproductions translations microfilms and the Feeding and processing in electronic systems Manufactured in 2022 by KMW Kühlmöbelwerk Limburg GmbH Limburger Strasse 80 D 65555 Limburg Article number 3042585 Imprint KMW Kühlmöbelwerk Limburg GmbH Gewerbegebiet Offheim Limburger Straße 80 D 65555 Limburg Tel 49 0 64 31 5 99 0 Fax 49 ...

Отзывы:

Похожие инструкции для Usedom