2. Installation of the KMS Sequential driver module
2.1 Installation notes
The KMS Sequential driver module is splash waterproof. However, it is best
to place it in a dry place where temperatures don’t exceed 65 °C.
Warning
: do not place the Sequential driver and it’s wires nearby any ‘high
powered’ cables such as sparkplug leads, as it can cause electrical
interference resulting in malfunction.
2.2 Wiring basics
Included with the KMS Sequential driver is a breakout wiring loom which
consists out of a main connector with all wires connected. These wires are
colour-coded according to their functions which can be found in the table
on the next page.
Both the +12v power input and the power ground should be connected to
the same stable power source as the ECU. It is highly recommended to
install a 10A fuse on the +12v line to prevent further damage in case of a
malfunction.
Connect the desired injector outputs to their corresponding injectors in
either firing order or cylinder order. The resulting injection order and
cylinder bank can later be set in the software (chapter 4: Software
settings).