2.6
Automatic gas level indicator calibration (NEVO and NEVO-SKY only,
for NEVO available from 4.0D version)
This process allows you to automatically configure the full range of gas level indication
on the panel driver. Prior to calibration, it is necessary to select the right type of gas level
sensor.
Automatic calibration should be performed during the refueling of empty gas tank. The
whole procedure is as follows:
1.
Turn the ignition on (gas tank should be empty).
2.
Switch system to petrol (panel is completely blank).
3.
Turn the ignition off.
4.
Turn the ignition on (the engine cannot work).
5.
Press the button on the control panel, and hold for about 15 sec. (available to NEVO
4.0G version) or 20 sec. (newer versions). After about 10 seconds the gas ECU open
the valves and indicates working on gas (you can hear longer beep from drivers
panel).
6.
After about 5 sec. (to NEVO 4.0G) or 10 sec. (newer versions) after the gas valve
opening (the button is still pressed) panel will indicate the calibration mode of the
gas level indicator
–
gas level LEDs flash alternately.
or
7.
Wait about 5 seconds to write down stable minimum level of gas.
8.
Turn the ignition off.
9.
Fuel the gas tank.
10.
Turn the ignition on.
11.
Wait until the panel stops indicating the calibration mode.
12.
Calibration finished.
WARNING!
It is possible to exit from the automatic calibration gas level indicator by pushing
the button again (the LED on the panel will go off and the system goes on petrol).
WARNING!
If panel indicates wrong fuel level after calibration it could mean that it was
made improperly
–
repeat the process before next refueling.