14
8. To mount the combination onto a wall, the clamp has a hole into which the regulator fits in and is
secured by the nut provided in the regulator itself.
Before Each Use
WHERE TO INSTALL A FILTER?
Install as far away from the compressor as possible. This allows air to cool and moisture to condense.
It is easier to remove condensed moisture than vapers. Place unit:
•
As close to tool/equipment as possible,
•
Before Regulator and Lubricator, and
•
With arrows pointing in direction of air flow (towards tool/equipment).
WHERE TO INSTALL A REGULATOR?
•
As close to tool or equipment as possible to avoid any further pressure loss,
•
Between the filter and lubricator, and
•
With arrows pointing in the direction of air flow (towards tool/equipment).
WHERE TO INSTALL A LUBRICATOR?
•
As close as to tool or equipment to avoid any further pressure loss,
•
Lubricator should be the last component in the FRL series, and
•
With arrows pointing in the direction of air flow (towards tool/equipment).
Thread Size
Tightening Torque,
Lb. - In (Nm)
Length (L) of Thread
G1/4
106 - 125 (12 - 14)
8 mm Max.
G3/8
195 - 215 (22 - 24)
9 mm Max.
G1/2
250 - 270 (28 - 30)
12 mm Max.
Operating Instructions
Refer to the parts diagrams and parts lists.
1. To set the regulator, pull the re
gulating knob till “Red Band” (indicator ring) is visible.
2. To increase the pressure, turn the regulating knob in a clockwise direction.
3. To reduce the pressure, turn the regulating knob in counter-clockwise direction.
4. Always set the pressure in the ascending manner.
5. Set the pressure within the specified limit.
6. To drain the condensate water collected in the bowl (7.1.1
“Air Filter”), press and hold the knob of
the drain valve (7.2 Air Filter).
Содержание 48575
Страница 10: ...10 AIR REGULATOR ...
Страница 12: ...12 AIR LUBRICATOR ...