background image

 

5 OF 7                                                                                       

 

 

2.  An air pressure of 90 PSI is required. 
3.  Drain the air tank daily. Water in the airline can damage the tool. 
4.  Clean the air inlet filter weekly. 
5.  Line pressure should be increased to compensate for longer air hoses (over 26 feet or 8 

meters).   

6.  Keep the hose away from heat, oil and sharp edges. Check the hose for wear and make 

certain that all connections are secure. 

MAINTENANCE 

WARNING:

 Make sure the Central Vacuum Random Orbital Sander is disconnected from its power 

source before attempting any maintenance, cleaning, or inspection. 

  Maintain your Central Vacuum Random Orbital Sander. It is recommended that the general 

condition of any tool be examined before it is used. Keep your Central Vacuum Random Orbital 
Sander in good repair by adopting a program of conscientious repair and maintenance in 
accordance with the recommended procedures found in this manual. If any abnormal vibrations or 
noise occurs, turn the Central Vacuum Random Orbital Sander off immediately and have the 
problem corrected before further use. Have necessary repairs made by qualified service personnel. 

  Keep all cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges 

are less likely to bind and are easier to control. Keep handles dry, clean, and free from oil and 
grease.   

  Cleaning. Use only soap and a damp cloth to clean your Central Vacuum Random Orbital Sander. 

Many household cleaners are harmful to plastics and other insulation. Never let liquid get inside the 
Central Vacuum Random Orbital Sander. 

 

OPERATING INSTRUCTIONS 

Check if the maximum air pressure is set to the specified value.

 

Setting the speed 

Use the speed regulator handle to adjust the speed regulator to the preferred speed.

 

Installing sanding discs 

 

Stick the Velcro sanding discs to the sanding pad.   
The discs must be centered and the dust extraction holes must be aligned with the sanding pad.

 

Connecting a dust extractor 

 

Connect a dust extractor unit to the suction connection. 

To prevent damage to the pneumatic motor let the dust extraction run for a short period after the tool has 
stopped.

 

Check if the sanding pad is fitted properly 

 

If the sanding pad is no longer adhesive, you should change to a new one. To change for it, turn up the 
shroud and insert the supplied wrench to fix the screw bolt in the central then turn the pad as shown in 
the illustration as below. 
Let the tool run at free speed for 30 s in a safe position.   
Stop immediately if vibration is too high or other problems are detected.   

 
 

Содержание 19982

Страница 1: ...RANDOM ORBITAL SANDER OWNER S MANUAL WARNING Read carefully and understand all INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious...

Страница 2: ...tal Sander provides effortless power and enough speed to complete a variety of drilling applications Its right angle head is ideal for use in tight quarters providing better efficiency and productivit...

Страница 3: ...ntral Vacuum Random Orbital Sander may result in serious personal injury Dress properly Do not wear loose clothing dangling objects or jewelry Keep your hair clothing and gloves away from moving parts...

Страница 4: ...egulator and oiler All of these components are sold separately NOTE If you are not using an automatic oiler system before operation add a few drops of Pneumatic Tool Oil to the airline connection Add...

Страница 5: ...d cutting tools with sharp cutting edges are less likely to bind and are easier to control Keep handles dry clean and free from oil and grease Cleaning Use only soap and a damp cloth to clean your Cen...

Страница 6: ...29 MOTOR SHAFT BALANCER 6 1 10 70426 AIR INLET 1 32 OB 30 SNAP RING 1 11 OB 11 MUFFLER BODY 33 OB 31 3 BEARING 6001LU 1 12 OB 11 1 O RING 33A OB 31 4 BEARING 6001 1 13 OB 11 EXHAUST SLEEVE 34 81326 PI...

Страница 7: ...or other reproductive harm Some examples of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products and arsenic and chromium from chemical...

Отзывы: