Klimawent ERGO-FLEX LUX Скачать руководство пользователя страница 3

 

 3 

 

 

 

 

10.01.2019                                

Extraction Arm

  ERGO-FLEX LUX  

 

 

 

1.  Introductory Remarks 

The purpose of the present Use and Maintenance Manual  is to supply User with directions wi-
thin the range of application, installation,

 

start-up  and the use

 

of 

the 

ERGO-FLEX LUX Extrac- 

tion Arms

 

Installing, start up and operational use are exclusively admissible after getting acquaint- 
ted with the contents of the Use and Maintenance Manual

With regard to continuity of work carried on 

improvement

 of our

 

products, we reserve for oursel- 

ves the revision possibility of the draft  and  technological changes improving  
their functional features and safety. 

 

The construction of the  

ERGO-FLEX LUX 

Extraction Arms

  

meets the requirements of the 

cur- 

rent state 

of technology

  

as well as the safety and health assurances included in: 

 

  2006/42/EC

 

Machinery Directive 

of the European Parliament and of the Council of 17 May, 

2006  on machinery 

– amending the 95/16/EC (recast)

 /

Journal of Laws EC L157 of 09.06.2006, page 24

/

 

 

The appliance meets following harmonized standard: 

 

 

PN-EN ISO 12100:2012 

 
 

 

“Safety of machinery.  Basic concepts, general principles for 

 

 

 

design.  Risk assessment and risk reduction”. 

 
 
 

2.  Application 

ERGO-FLEX LUX  Extraction Arms

 

 

have been developed for capturing the welding dust parti- 

cles and welding gas as well as other

 fine dust particles,  directly at the emission source, in order  

to avoid the contamination expanding within the process room/hall and protect the people in the 
vicinity from inhaling the contamination. 
The extraction arms are manufactured in hanging

 and

 

standing version. They can work indepen- 

dently, in a single configuration with one extraction fan,

  

or in a group of extraction arms, connec- 

ted to the main collecting ducting  (with a central fan). 
 
 
 

 

3.  Reservations of Producer 

 

A. 

Manufacturer is not liable for  any consequences following from the operational use that is  
in contradiction to the purpose of application. 

 

 

B. 

Do 

not install any

 additional elements 

not belonging to the normal device

 structure or acces-

sory set. 

 

 

C. 

Any structural changes  or modifications on the appliance  

on one’s own are not permitted. 

 

 

D. 

Protect the flexible elements of the arm from mechanical damage. 

 

 

E. 

Before the installing, check the load carrying capacity of the wall / building structure in pla- 

ces where

 the appliance

 shall be installed.

  

Unsure mounting 

could cause damage of the de-

vice,  risk to personnel / people in the vicinity. 

 

 

F. 

The appliance must not be used

 for conveying the air containing aggressive contami-

nation. 

 
 

 

Содержание ERGO-FLEX LUX

Страница 1: ...1 10 01 2019 Extraction Arm ERGO FLEX LUX Use and Maintenance Manual Extraction Arms ERGO FLEX LUX ...

Страница 2: ... Reservations of Producer 3 4 Technical Data 4 5 Structure and Function 7 6 Assembly and Start up 7 7 Operational Use 8 8 Troubleshooting Guide 9 9 Maintenance 9 10 Occupational Health and Safety 9 11 Transport and Storage 10 12 Terms of warranty 10 13 Sample of the Declaration of Conformity 13 ...

Страница 3: ...tion 2 Application ERGO FLEX LUX Extraction Arms have been developed for capturing the welding dust parti cles and welding gas as well as other fine dust particles directly at the emission source in order to avoid the contamination expanding within the process room hall and protect the people in the vicinity from inhaling the contamination The extraction arms are manufactured in hanging and standi...

Страница 4: ...m mm mm mm mm mm mm kg ERGO FLEX LUX 2 Ø160 2 930 435 355 Ø194 6 x Ø6 5 Ø295 8 5 ERGO FLEX LUX 3 3 1510 846 9 6 ERGO FLEX LUX 4 4 1890 1435 10 2 ERGO FLEX LUX 2 R 2 1230 435 8 4 ERGO FLEX LUX 3 R 3 1810 846 9 1 ERGO FLEX LUX 4 R 4 2190 1435 9 8 Fig No 1 Dimensions of the extraction arms type ERGO FLEX LUX ...

Страница 5: ...GO FLEX LUX Table No 2 Hood Type G Z T H Application Weight mm mm mm mm kg LST Ø295 Ø365 Ø170 190 ERGO FLEX LUX 2 ERGO FLEX LUX 3 ERGO FLEX LUX 4 ERGO FLEX LUX 2 R ERGO FLEX LUX 3 R ERGO FLEX LUX 4 R 0 42 Flow chart ERGO FLEX LUX 2 ...

Страница 6: ...6 Extraction Arm ERGO FLEX LUX 10 01 2019 Flow chart ERGO FLEX LUX 3 Flow chart ERGO FLEX LUX 4 ...

Страница 7: ...ng provide the comfort of easy manoeuvring with the extraction arm 6 Assembly and Start up ERGO FLEX LUX extraction arms along with the hoods are delivered in separate cardboard packages The suction hood has to be fastened according to the Assembly instruction of the ERGO FLEX LUX extraction arms on page 11 Diameters and the hole pattern for the mounting bolts are identical in the wall bracket and...

Страница 8: ...sed position ope rational state or if it causes obstacle set the arm into the home position Switch off the extraction fan in case where the extraction arm works in a ventilation system close the shut off damper 7 Operational Use In general the device construction guarantees a safe and reliable function without continuous routine servicing and special handling If necessary undertake the adjustment ...

Страница 9: ... most efficient capture In application for wel ding dusts sprinkle additionally them with the anti gluing anti spattering fluid against chip pings In case when the extraction arm is losing its self supporting properties undertake the ad justment of its frictional brakes Lubricate the swivel every 3 months using solid grease lubrication nipple is located on the swivel flange After 1 operational yea...

Страница 10: ...he purchased device is indicated in the Card of Warranty The warranty does not comprise device failures caused during use which was in contradiction with the purpose of operatio nal use and with the present Use and Maintenance Manual mechanical electrical damages and malfunctions caused by User modifications and changes on the appliance undertaken by User on one s own inefficiency or malfunctions ...

Страница 11: ...frictional joint at the swivel in such a way that the extraction arm is easy to ma noeuvre and is stable in keeping the requested arm position 5 Sleeve the hose onto the swivel and fold up the hose edge inwards and subsequently se cure it with a hose clamp 6 Adjust the middle joint similarly as in Clause 4 7 Install the hood at the extraction arm according to the Detail A Adjust the frictional joi...

Страница 12: ...ping the requested arm position 4 Sleeve the hose onto the swivel and fold up the hose edge inwards and subsequently se cure it with a hose clamp 5 Adjust the middle joint similarly as in Clause 3 6 Install the hood at the extraction arm according to the Detail A Adjust the frictional joint of the hood in such a way that it is easy to manoeuvre with the hood and it is keeping the requested operati...

Страница 13: ... May 2006 on machinery amending the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The device has been constructed and produced on the basis of following harmonized standards PN EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduction place date signature of authorised person name surname function of the signatory KLIMAWEN...

Страница 14: ...14 Extraction Arm ERGO FLEX LUX 10 01 2019 NOTES ...

Страница 15: ...15 10 01 2019 Extraction Arm ERGO FLEX LUX NOTES ...

Страница 16: ...629 64 80 fax 058 629 64 19 e mail klimawent klimawent com pl www klimawent com pl 810R42 ERGO FLEX LUX 2 10 01 2019 EN 810R43 ERGO FLEX LUX 3 10 01 2019 EN 810R44 ERGO FLEX LUX 4 10 01 2019 EN 810R45 ERGO FLEX LUX 2 R 10 01 2019 EN 810R46 ERGO FLEX LUX 3 R 10 01 2019 EN 810R47 ERGO FLEX LUX 4 R 10 01 2019 EN ...

Отзывы: