14 z 20 

Filtering unit

 

BIG-10000/Ex

 

08.10.2019 

 

 

7.3  Startup of the system

 

Connect the elements strictly according to the diagram, using cables selected with reference to current-carrying 
capacity of the receivers. 

 

Switch on the protections in the switchgear 

A1

 

Check if the 

F1

 fuse in the micro-controller 

A2

 is not damaged. 

 

Apply the supply voltage with the 

S1

 disconnector in the switchgear 

A1

 

Switch on the system with the 

S2 

switch. 

 

The fan can be safely started with the green button 

S3.2

 

– under the condition that the red lamp 

ALARM

 (on 

the 

A1

 switchgear door) in not on. 

 

When  the  green  lamp  (built  in  the  double  button 

S3

)  is  lighting 

–  this  is  the  information  that  the  fan  is  in 

operation and the filter regeneration system is switched on; {To make sure, the filter regeneration system is 
functioning 

– after the first device startup, examine the device,  check (after the ALARM state emerges) the 

communicates  emerging  on  the  micro-controller  display}.  Additionally,  after  the  first  start-up,  check  the 
rotation sense of the fan impeller. 

 

To switch off the fan 

– press the red button 

S3.1

 

The green lamp (build in the button) goes off 

– subsequently, proceeds the final filters regeneration – at any 

time the fan can be started again. 

 
7.4  Alarms

 

In the device can appear states of alarms, caused by: 

 

activation of the motor protective switch 

 

interruption of the sensors on the decompression membrane, 

 

alarm from the micro-controller  (controlling the function of the electromagnetic valves)  

–  description in 7.2. 

These  alarms  are  signalised  by  the  red  lamp 

H2

  (placed  on  the  door  of  the  switchgear 

A1

).  When  the  alarm 

occurs,  it  is  important  to  disconnect  the  power  supply  by  means  of  the 

S1

  disconnector.    Next,  find  the  fai-

lure/damage,   find out its/their reason  and  remove the malfunction.  After the failure is removed correctly, and 
the power supply is applied again 

– the filtering unit can be operated again. 

 
On the  appliance is  installed  a temperature sensor.  At the moment  when the temperature of the conveyed air 
exceeds 40

– an acoustic signal (buzzer) activates – this is signalised by the H4 “HIGH TEMPERATURE” lamp. 

Operators should react and switch off the device. If the device is not switched off by the operator 

– it will work 

longer and when the temperature exceeds 45

– it will switch off automatically. Indications of temperature are 

shown in the upper line of the governor / thermostat REG1. 

CAUTION

:  

If the

 

fan

 

works incorrectly, please contact the Deliverer

 

7.5  Removal of dust

 

The dust must be emptied systematically, when the waste container is filled up. User has to give instructions to 
the operating personnel, that 

while disconnection of the waste container from the hopper 

(

by means of the 

blocking lever

)

 they must take precautions

. In case when the waste container is not sufficiently supported from 

underneath,  it  can  be  rapidly  discarded  (thrown  away).    Mind,  the  workers  should  necessarily  wear  antistatic 
clothes.  Additionally, the waste container (while withdrawal, mounting) must be placed on an antistatic pad. 
This activity should be carried out, after the fan is switched off and the device disconnected from the power supply 
mains.  When the waste container is fastened back to the device, mind that the contact surfaces are clean and the 
seal is suitable to the edge between the waste container and the hopper chamber. 
 

7.6  Measures of precautions during the maintenance 

 

The filtering unit must be used according to the present Use and Maintenance Manual and according to the 
being in force regulations. 

 

Maintenance steps / activities should be executed by authorised workers after the instructions. 

 

In the course of operational use, be careful that no ignition sources (e.g. sparks, cigarette butts, embers) 
gets into the device. 

 

During the emptying of the waste container and during any other activity near the filtering unit, it is important 
to wear antistatic clothes.  Put the antistatic pad/rug underneath the waste container. 

 

Directly,  at  the  filtering  unit,  and  in  the  vicinity 

–  do  not  use  mobile  phones  and  other  devices  emitting 

electromagnetic waves. 

 
 

 

Содержание BIG-10000/Ex

Страница 1: ...UNCTION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 15 MAINTENANCE AND REPAIR 15 OCCUPATIONAL HEALTH AND SAFETY 16 TRANSPORT AND STORAGE 16 TERMS OF WARRANTY 16 DECLARATION OF CON...

Страница 2: ...Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gen...

Страница 3: ...0 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigarette butts embers from getting into the filtering unit 3...

Страница 4: ...ified as zone 22 Fig No 2 Classification ATEX internal zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 10000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upp...

Страница 5: ...the fan chamber are delivered upon separate order 5 2 Function BIG 10000 Ex filtering unit provides separation of the air containing dry dust fraction The dust laden air is guided to the chamber of f...

Страница 6: ...ice of 9 cartridge filters and at the nominal diameter of the compressed air tank of 8 should be 1 1 2 6 2 Start up Upon first operation of the compressed air installation of the device check if the c...

Страница 7: ...erson according to being in force regulations in this range Any device modification change within the construction and mounting without the consent of deliverer shall cause the invalidation of conform...

Страница 8: ...al 7 1 Description of the control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed...

Страница 9: ...e price 08 10 2019 Filtering unit BIG 10000 Ex 9 z 20 Fig No 11 Switchgear A1 internal view Micro controller A2 provides control of the electromagnetic valves the function is described in Section 7 2...

Страница 10: ...omation disconnects the fan and the system of regeneration of filters Any electrical connections ought to be performed in conformity with the above placed Connection Diagram see Fig No 7 8 9 Motor in...

Страница 11: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 11 z 20...

Страница 12: ...Klimawent the warranty of highest quality at attractive price 12 z 20 Filtering unit BIG 10000 Ex 08 10 2019...

Страница 13: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 13 z 20...

Страница 14: ...the appliance is installed a temperature sensor At the moment when the temperature of the conveyed air exceeds 40 C an acoustic signal buzzer activates this is signalised by the H4 HIGH TEMPERATURE l...

Страница 15: ...filters are damaged or worn out replace them for new The filters should be drawn out beginning from the filter closest to the inspection door Before User draws out the filter first release the mountin...

Страница 16: ...nge of personal protection against electric shock Connection to the power supply system should be executed by an authorised person with electrical qualifications Maximum operational pressure of the co...

Страница 17: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in poten...

Страница 18: ...Klimawent the warranty of highest quality at attractive price 18 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Страница 19: ...Klimawent the warranty of highest quality at attractive price 08 10 2019 Filtering unit BIG 10000 Ex 19 z 20 NOTES...

Страница 20: ...Klimawent the warranty of highest quality at attractive price 20 z 20 Filtering unit BIG 10000 Ex 08 10 2019 NOTES...

Отзывы: