KlimaTeknik Top Heat pump
- 5 -
3.3 Distance from your swimming pool
The heat pump is normally installed within a perimeter area extending 7.5 m from the swimming pool. The
greater the distance from the pool, the greater the heat loss in the pipes. As the pipes are mostly
underground, the heat loss is low for distances up to 30 m (15 m from and to the pump; 30 m in total)
unless the ground is wet or the groundwater level is high. A rough estimate of the heat loss per 30 m is
0.6 kWh (2,000 BTU) for every 5 ºC difference between the water temperature in the pool and the
temperature of the soil surrounding the pipe. This increases the operating time by 3% to 5%.
3.4 Check-valve installation
Note: If automatic dosing equipment for chlorine and acid (pH) is used, it is essential to protect the heat
pump against excessively high chemical concentrations which may corrode the heat exchanger. For this
reason, equipment of this sort must always be fitted in the piping on the
downstream
side of the heat
pump, and it is recommended to install a check-valve to prevent reverse flow in the absence of water
circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.
Содержание KT135CV-TOP
Страница 1: ...KlimaTeknik Top Heat Pump HEAT PUMPS HEAT PUMPS ...
Страница 4: ...KlimaTeknik Top Heat pump 3 2 Dimensions Model KT135CV TOP Model KT300CV TOP ...
Страница 12: ...KlimaTeknik Top Heat pump 11 5 Electrical Wiring 5 1 Electrical wiring diagram for KT135CV TOP ...
Страница 25: ...KlimaTeknik Top Heat pump 4 4 Parameter setting Click Parameter Setting then enter the Password 0757 ...
Страница 27: ...KlimaTeknik Top Heat pump 6 5 Parameter setting Click Parameter query ...
Страница 30: ...KlimaTeknik Top Heat pump 9 9 Exploded Diagram Model KT135CV TOP ...
Страница 33: ...KlimaTeknik Top Heat pump 12 ...
Страница 34: ...KlimaTeknik Top Heat pump 13 ...
Страница 35: ...KlimaTeknik Top Heat pump ...
Страница 36: ...KlimaTeknik Top Heat pump ...