background image

Pipe connection

● 

Connect 

the pipe to the unit: point to the 

    center of  pipe and fasten by wrench 
    until it is tightly 
    fastened, the 
    fastening 
    direction is in the 
    following picture.

Indoor unit

Pipe

Connection screw

Torque 
wrench

Wrench

Connection screw

The size of pipe

6.35mm(    )

9.52mm(    )

12.7mm(    )

15.88mm(    )

Torque

18N.m
13.3 lb-ft
42N.m

55N.m

75N.m

1

3

1

5

_
_
_

_

4

8

2

8

● 

Pointing towards the center of pipe, fasten 

    the screw with strength.

● 

Wrench the screw in the end until you hear 

    the “Click” sound. 

Refer the direction to the picture

Outdoor unit

Torque wrench

Side air pipe

Side liquid pipe

The form of pipe

● 

Wrap 

up all pipe, water discharge and 

    connection wire from top to below.

● 

Cover 

the connection and fix them with 

    two plastic rings.

● 

Wrap 

up the pipes with tape alongside 

    the wall and fix them to the wall with 
    clips. These steps are usually adopted 
    when outdoor unit is installed below the 
    indoor unit.

Use sealing tape to 
cover the small leaks 
on the external ring 
of the pipe

Wrap up with tape

Pipes 

Water discharge 

pipe

Connection wire 

Control panel cover

Connection wire 

Round in this shape to prevent water 
entering the electrical parts

Round shape

Round shape

Use sealing tape to 
cover the small leaks 
on the external ring of 
the pipe

See the picture 
on the left

● 

In 

case that you want to have 

    additional water discharge pipe, the 
    end of pipe should be within certain 
    distance towards to surface ( don't let 
    it under the water. Fix it onto the wall 
    so it won't be swayed by the wind).

● 

Wrap 

the pipes and connection wire 

    well from below to top.

● 

Wrap up the pipes that are rounded 

    up by the wall comers in the way 
    shown in the picture so it can prevent 
    water entering the room.

● 

Use 

clips or other fixture to fasten the 

    pipes to the walls.

- 14 -

31 lb-ft

41 lb-ft

55 lb-ft

Содержание KSIX024-H220

Страница 1: ...how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many an...

Страница 2: ...8 10 11 12 13 14 16 17 17 4 Test running Packing list Operation Notices Care and Maintenance Troubleshooting Installation Guide Selection of the installing position Installation of the indoor unit In...

Страница 3: ...user maintenance shall not be made by children without supervision Only for the AC with CE MARKING 2 This appliance is not intended for use by persons including children with reduced physical sensory...

Страница 4: ...outlet or inlet As a fan is rotating at a high speed it will cause injury 15 Don t touch the swinging wind vanes It may clamp your finger and damage the driving parts of the wind vanes 16 Don t attemp...

Страница 5: ...m outer environments such as mobile phone please cut off the plug and plug in to restart the air conditioner after several seconds 9 It is forbidden to let the air conditioner keep precision instrumen...

Страница 6: ...municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dump...

Страница 7: ...on information and actual appliance Please refer to the real appliance purchased Thank you 5 Indoor Unit Name of Each Part Indoor Unit Outdoor Unit 1 Front panel 2 Air filter 3 Handling switch 4 Louve...

Страница 8: ...air conditioner remote controller instruction for how to adjust horizontal air flow Adjusting air flow direction 1 orizontal air flow manually Adjusting h Remote controller operation See air conditio...

Страница 9: ...es please contact our Service center locally Checking before operation To prevent injury and property damage Please pay attention to these following before operating the air conditioner N 842 2006 If...

Страница 10: ...and then take it out 2 Use a vacuum cleaner or wash them with water then dry it in the shade 3 Reinsert the air filter into the indoor unit until being entirely fixed then close the front panel 1 Sel...

Страница 11: ...ir of the room is cooled down rapidly by the cold wind and it looks like the fog This generate due to moisture in defrosting process Low noise can be heard during operation A low hissing sound is caus...

Страница 12: ...6 The air conditioner must be well grounded the switch of the main power of air conditioner must be reliably grounded Guide for customer Notices 1 The air conditioner must be installed on well strong...

Страница 13: ...doorway Make sure to have the distance between the ceiling wall furniture and other obstacles 2 meters high above the floor In case that you put up a canopy to protect it from rains and sunrays pay a...

Страница 14: ...hanges to wall and make sure that is hard and secure Using four type screws to fasten the installation board onto the wall Keep it water lever horizontal direction and perpendicular in vertical direct...

Страница 15: ...ensure the normal operation of the fan and the blocking plate should be used If it will be installed in type the structure of the mounting surface should be made of solid stick cement or materials wi...

Страница 16: ...fix them to the wall with clips These steps are usually adopted when outdoor unit is installed below the indoor unit Use sealing tape to cover the small leaks on the external ring of the pipe Wrap up...

Страница 17: ...the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare mut of the Lo valve on the gas pipe side and check that the air is enterin...

Страница 18: ...onnection plug Connection plug Outdoor unit terminal block L N S V F Yellow green To power To indoor unit Yellow green Brown Blue L N S V F L N S V F Yellow green To power To indoor unit Yellow green...

Страница 19: ...emperature Make sure whether the outlet air temperature subtract from inlet s gives more than 10 C Test running Discharged air Packing list Please check the following attach carefully if part attach i...

Страница 20: ...ace Doral FL 33172 USA The Klimaire logo is a registered Trademark of Klimaire Products inc Copyright 2014 Klimaire Products Inc The design and specifications are subject to change without prior notic...

Отзывы: