 Troubleshooting 9 

Displayed code

Explanation

Displayed 

value

Meaning

Additional Notes

T1

T2

T3

T4

Tb

TP

TH

FT

Fr

Room temperature

-1F,-1E,-1d,-1c,-
1b,-1A

-19—99

A0,A1,…A9

b0,b1,…b9

c0,c1,…c9

d0,d1,…d9

E0,E1,…E9

F0,F1,…F9

-25,-24,-23,-22, 
-21,-20

-19—99

100,101,…109

110,111,…119

120,121,…129

130,131,…139

140,141,…149

150,151,…159

1.  All displayed temperatures 

use actual values.

2.  All temperatures are 

displayed in °C regardless 
of remote used.

3.  T1, T2, T3, T4, and T2B 

display ranges from -25 to 
70 °C. TP display ranges 
from -20 to 130 °C.

4.  The frequency display 

ranges from 0 to 159HZ.

5.  If the actual values exceed 

or fall short of the defined 
range, the values closest 
to the maximum and 
minimum values will be 
displayed.

Indoor coil 
temperature

Outdoor coil 
temperature

Ambient 
temperature

Outlet temperature 
of indoor coil

Discharge 
temperature

Suction temperature

Targeted frequency

Actual frequency 

IF

Indoor fan speed

0

1,2,3,4

14-FF

OFF

Low speed, Medium 
speed, High speed, 
Turbo.

Actual fan speed is 
equal to the display 
value converted to 
decimal value and 
multiplied by 10. This 
is measured in RPM.

N/A

Used for some large capacity 
motors.

Used for some small capacity 
motors.

The display value is 14-FF  
(hexadecimal). The 
corresponding fan speed 
ranges from 200 to 2550RPM.

OF

Outdoor fan speed

LA

EXV opening angle

0-FF

Actual EXV opening 
value is equal to 
the display value 
converted to decimal 
value and then 
multiplied by 2.

-

CT

Compressor 
continuous running 
time

0-FF

0-255 minutes

If the actual value exceeds 
or falls short of the defined 
range, the value closest to the 
maximum and minimum will 
be displayed.

ST

Causes of 
compressor stop

0-99

For a detailed 
explanation, contact 
technical support.

-

Содержание KSIV SERIES

Страница 1: ...KSIV SERIES TROUBLESHOOTING SERVICE MANUAL...

Страница 2: ...error diagnosis and solution 18 7 2 E1 Indoor and outdoor unit communication error diagnosis and solution 19 7 3 E2 Zero crossing detection error diagnosis and solution 21 7 4 E3 F5 Fan speed is oper...

Страница 3: ...trong current protection diagnosis and solution 29 7 10 P1 Over voltage or too low voltage protection diagnosis and solution 30 7 11 P2 High temperature protection of IPM module diagnosis and solution...

Страница 4: ...tatic gloves or wrist strap to avoid damage to the board WARNING Electricity remains in capacitors even when the power supply is off Ensure the capacitors are fully discharged before troubleshooting T...

Страница 5: ...erant leak detected TS27 1 times ON F0 Current overload protection TS28 2 times ON F1 Outdoor room temperature sensor T4 is in open circuit or has short circuited TS25 3 times ON F2 Condenser coil tem...

Страница 6: ...D RED Solution 1 Standby normally ON OFF 2 Operate normally OFF ON 3 Compressor driven chip EEPROM parameter error ON FLASH TS18 4 IPM malfunction or IGBT over strong current protection Flash OFF TS29...

Страница 7: ...outlet C F Installation Condition Information Indoor temperature C F Indoor humidity RH Outdoor temperature C F Outdoor humidity RH Length of Connecting pipe Pipe diameter Gas pipe Liquid pipe Length...

Страница 8: ...oor coil temperature T4 Ambient temperature Tb Outlet temperature of indoor coil TP Discharge temperature TH Sunction temperature FT Targeted Frequency Fr Actual Frequency IF Indoor fan speed OF Outdo...

Страница 9: ...hear beeps for two seconds which means the unit goes into parameter checking mode Use the LED or DO NOT DISTURB and SWING or AIR DIRECTION buttons to cycle through information displayed Pressing LED o...

Страница 10: ...ture Ambient temperature Outlet temperature of indoor coil Discharge temperature Suction temperature Targeted frequency Actual frequency IF Indoor fan speed 0 1 2 3 4 14 FF OFF Low speed Medium speed...

Страница 11: ...Troubleshooting 10 Displayed code Explanation Displayed value Meaning Additional Notes A0 Reserved 0 FF 2 28 5 20 5 25 A1 0 1 2 3 4 5 6 L A U T A 5 T...

Страница 12: ...field maintenance No Problem Solution 1 Unit will not start TS13 TS14 2 The power switch is on but fans will not start TS13 TS14 3 The temperature on the display board cannot be set TS13 TS14 4 Unit...

Страница 13: ...TS16 5 Condenser Outdoor fan will not start TS15 TS16 6 Unit runs but shortly stops TS15 TS16 7 Compressor short cycles due to overload TS15 TS16 8 High discharge pressure TS15 TS16 9 Low discharge p...

Страница 14: ...frequently Unit will not start The power switch is on but fans will not start The temperature on the display board cannot be set Unit is on but the wind is not cold hot Unit runs but shortly stops The...

Страница 15: ...switch is on but fans will not start The temperature on the display board cannot be set Unit is on but the wind is not cold hot Unit runs but shortly stops The unit starts up and stops frequently Unit...

Страница 16: ...Condenser Outdoor fan will not start Unit runs but shortly stops Compressor short cycles due to overload High discharge pressure Low discharge pressure High suction pressure Low suction pressure Unit...

Страница 17: ...art but fans run Compressor and condenser outdoor fan will not start Evaporator indoor fan will not start Condenser Outdoor fan will not start Unit runs but shortly stops Compressor short cycles due t...

Страница 18: ...Sensor x x x x x x x T3 Sensor x x x x x x x x x T4 Sensor x x x x x x x x x TP Sensor x x x x x x x x x Reactor x x x x x x x x Compressor x x x x x x x x Additional refrigerant x x x x x x x x Part...

Страница 19: ...CB F4 The unit is operating normally NO Remarks EEPROM A read only memory whose contents can be erased and reprogrammed using a pulsed voltage The location of the EEPROM chip on the indoor and outdoor...

Страница 20: ...N YES Is the voltage moving alternately between Positive and negative Check the outdoor wiring connection Is it normal Check the reactor YES Is it normal Replace the outdoor PCB Power on YES Is the e...

Страница 21: ...ernately between 25V to 25V If the outdoor unit has malfunction the voltage will move alternately with positive value While if the indoor unit has malfunction the voltage will be a certain value Use a...

Страница 22: ...rval is abnormal Recommended parts to prepare Connection wires PCB Troubleshooting and repair Check the connections and power supply Correct the connections Turn on the unit when the power supply is g...

Страница 23: ...tart the unit after 2 minutes Is it within normal parameters Replace the fan motor Does a problem remain The unit is operating normally NO Shut off the power supply Rotate the fan by hand YES Does it...

Страница 24: ...Color Signal Voltage 1 Red Vs Vm 280V 380V 2 3 Black GND 0V 4 White Vcc 14 17 5V 5 Yellow Vsp 0 5 6V 6 Blue FG 14 17 5V DC motor voltage input and output voltage 115V No Color Signal Voltage 1 Red Vs...

Страница 25: ...t the unit running in fan mode at high fan speed After running for 15 seconds measure the voltage of pin1 and pin2 If the value of the voltage is less than 100V 208 240V power supply or 50V 115V power...

Страница 26: ...repair Check the connection between temperature sensor and PCB Replace indoor PCB E4 E5 or outdoor PCB F1 F2 F3 Is it within acceptable parameters Is it properly wired Ensure proper connections NO Me...

Страница 27: ...s to prepare Communication wire Indoor PCB Display board Troubleshooting and repair Is it still displaying the error code The unit functions normally Check the wirings and connections Are all the conn...

Страница 28: ...on happens 3 times the display area will show EC and AC will turn off Recommended parts to prepare T2 sensor Indoor PCB Additional refrigerant Troubleshooting and repair Power off then restart the uni...

Страница 29: ...able parameters Are they properly connected Is it in working order Replace the outdoor unit Is it in working order Check system for blockages YES Stop the unit NO Clear the blockage Yes Check the comp...

Страница 30: ...Does an error exist Ensure proper connections or replace the wires and connectors YES Check the IPM NO Is it in working order Replace the IPM board or replace the outdoor PCB NO Check the outdoor fan...

Страница 31: ...the unit NO Check the connections and wires YES Are they in working order Ensure proper connections or replace the wires NO Power on and measure the voltage between P and N YES While the unit is in s...

Страница 32: ...ilure Recommended parts to prepare Outdoor PCB IPM module board Troubleshooting and repair Check the fastening screws on the PCB and IPM radiator Are they fixed tightly Replace the outdoor control PCB...

Страница 33: ...e wiring between the PCB and compressor Is it improperly wired Ensure proper connections or replace the wires and connectors YES Check the IPM NO Is it functioning properly Replace the IPM board or re...

Страница 34: ...r Unit Disassembly 2 Measure the resistance value of the sensor using a multi meter 3 Check corresponding temperature sensor resistance value table Refer to Chapter 8 Appendix Note The picture and the...

Страница 35: ...ooting 30 Resistance Value KSK103D33UEZ3 KSN140D21UFZ KTM240D57UMT Blue Red 2 02 1 28 0 62 Blue Black Red Black Note The picture and the value are only for reference actual condition and specific valu...

Страница 36: ...upply 2 Discharge electrolytic capacitors and ensure all energy storage unit has been discharged 3 Disassemble outdoor PCB or disassemble IPM board 4 Measure the resistance value between P and U V W N...

Страница 37: ...t improvement Consult with the sales agency or manufacturer for details 2190 NW 89 Place Doral FL 33172 USA Tel 305 593 8358 Fax 305 675 2212 www klimaire com sales klimaire com The Klimaire logo is a...

Отзывы: