the needed parameters such as: temperature of the water in the water heater, the hour, time at
the beginning and at the end of the water heating, choice of heating with one or two heaters,
choice of a mode.
5.3. The button (SW3), (SETTINGS) serves for change of the parameters such as: Temperature of the
water in the heater for water, hour, time of beginning and end of heating, choice of heating with one or
two heaters, choice of type of heating.
Example: In order to put the desired temperature at 60˚C, it is needed, by pressing the button (SW2), to
come to the place of the display where the temperature is shown and which is marked by No.1 on the
“CONTROL PANEL”. Then by pressing the button (SW3), you can change the temperature which is in
an interval (30-75˚C), by step of 5˚C. In order to choose whether we will heat the water in the heater by
heater 1 or heater 2, or by a combination of heater 1 and 2, it is needed, with the button (SW2), to arrive
to the part of the display where the two heaters are marked. Then, with the button (SW3) we make a
choice of a heater. By the same procedure, he clock is set, as well as the time for postponed heating of
the water and its end.
5.4. The button (SW4) (HEATERS) serves for turning on and turning off the heaters 1 and 2. If the heater
for the water is in a mode for postponed heating of the water, then by pressing the button (SW4) it will
change into a mode for heating the water at the desired temperature which we have set before. The
same can be changed during the heating.
- Each pressing of a button is followed by a tone.
6.MISTAKES:
If the following mistakes appear at the display, the system will stop working.
6.1 If a mistake E1 appears on the display, it means that the sonda (sensor) is interrupted.- Call
the service agency to determine the reason for the mistake.
6.2 If a mistake E2 appears on the display, it means that the water in the system is ≥80 ˚C. –The
maximum temperature is being reached.
6.3 If a mistake E3 appears on the display, it means that there is no water in the water heater.-
Call the service agency to check why the water heater is left without water.
6.4 If a mistake E4 appears on the display, it means that electric power higher than 22mA flows through
the protective conductor. – Call the service agency to determine where is the problem. When the heater
shall not be used during a longer time, it must be disconnected from the electric network. At any risk
for freezing of water in the water heater, the water must be emptied from it. Water is discharged
from the heater via the inlet pipe. To this purpose, a special fitting (t-fitting) shall be mounted between
the relief valve and the heater inlet pipe, or a discharge tap. Before discharge, make sure the heater is
disconnected from the power supply, open the hot water on the connected mixer tap. After discharging
through the inlet pipe, there is still some water left in water heater. The remaining water will be
discharged after removing the heating flange, through the heating flange opening. The external parts
of the water heater may be cleaned with a mild detergent solution. Do not use solvents and abrasives.
Regular preventive maintenance inspection and sure faultless performance and long live of your heater.
The lime coating and sediment on the walls of the tank and on the heating element is a product of
quality, quantity and temperature of the water flowing through the water heater. The maintenance
service provider shall also issue a condition report and recommend the approximate date of the next
inspection. Never try to repair any possible faults of the water heater by yourself, but inform