OPERATING THE LIFT TABLE
How to use the brake
The brake is located next to the swivel caster on right hand side.
1. To brake the lift table, press the brake pedal.
2. To release the brake, lift up the brake pedal.
CAUTION:
Put lift table in brake mode when stationary in order to prevent sudden movement.
Lifting the Table
To lift the table, press the lifting pedal several times until the table reaches the desired height. The table
lowers slightly after reaching the highest position. Maximum Capacity of this table is 1650 lbs. (750kg).
WARNING:
Do not overload lift table, stay within the rated capacity.
Do not load the table on sides or ends only. Load must be distributed on at least 80% of table area.
Lowering the Table
WARNING:
DO NOT put foot or hand in scissor mechanism. The rotating knob lowers the table.
NOTE:
The hydraulic cylinder is designed to hold table. As is the nature of the hydraulic system, table
lowers very slowly over an extended period of time. Please note that the table does not stay at the same
height indefinitely.
Specifications
Model
Capacity
Table
Table Height
Foot Pedal
Strokes to Elevate
Wheel
Weight
MJ523
750 kg.
1650 lbs.
1000 x 510 mm
39.4" x 20.1"
420-900 mm
16.5" x 35.4"
45
147 mm
5.75"
125 kg.
275 lbs.
Service Instructions
Change hydraulic oil every 12 months
Lubricate the following areas every month:
Fitting of Cylinder/oil, Roller Friction Surface/grease,
Link Pin/oil, Pedal Fitting Point/oil, Grease Nipple/grease
Troubleshooting
If the table does not lift when pressing lifting pedal several times:
• Adjust the control valve located on
the hydraulic cylinder (A) by releasing
the set screw and locking nut (B) using a
flat screwdriver and a 14mm wrench.
• Test the control lever and lifting pedal.
A
B