Operating instructions 

Operating instructions 

  

Preparation of the instrument 

To make the instrument usable for walking test you have to do : 

 

 

 

Measuring process 

For measuring the maximum values following those steps: 

 

 

 

The unit is now ready for operation

wait 2 Seconds to select MAX-Mode

press «function/on» multiple until «MAX-Mode» displayed»

Press and hold Button «function/on» (2) until «change cm» displayed

Switch on EFM 023 and wait until«Dist = 2cm» displayed

Connect CPS socket to ground

connect Hand electrode with Silicon cable to the measure input

screw theVoltage measuring head (5) on the spacers

replace the two spacers 20mm with metal spacer (4) 28mm

Mount the EFM 023 into the CPS-Socket

To start a new measure go to step one

Press «function/on» briefly to stop the maximum display

In the lower line the actually measure value displayed

In the upper line the maximum pos. and neg. value displayed

Take the hand electrode in you hand and start walking

Press «function/on» briefly to reset the maximum values 

Содержание EFM 023 BGT

Страница 1: ...MANUAL EFM 023 BGT System Prof Dr Ing Hans Kleinw chter Walking Test with EFM 023 and UAC 110...

Страница 2: ...nt ranges 7 E Field Meter Measurement 7 Max Value 7 Analog Output 7 Changing the measurement distance 8 Spacers 8 Display 9 Battery Monitoring 9 Grounding 9 Maintenance 9 Battery Replacement 10 Zero P...

Страница 3: ...aterial that releases electrons is charged positive The material admitting electrons is charged negative There are different ways to avoid or to discharge electrostatic charges But to find an effectiv...

Страница 4: ...esolution 10Bit Battery 9V alkaline or NiMH battery Operating time Approx 10h with alkaline battery Measuring range Voltmeter Distance Measuring range Max resolution 1cm 0 10kV 1V 2cm 0 20kV 2V 5cm 0...

Страница 5: ...M023 In the middle of the left side here is the output socket for the analog output 1 Cover cap 5 Spacer 2 Modulator system 6 Zero point trimmer 3 Button function on 7 Alphanumeric LCD display 4 Groun...

Страница 6: ...briefly to change to a new distance or to CPS mode wait approx 2s to select the displayed function Aus Press function on 2 times in quick succession Initiation By pressing the function on button on t...

Страница 7: ...Field Meter Mode In this Mode it s possible to select the following ranges 20KV m 200kV m or 1MV m To change the ranges press the function on key briefly The range changed as following In this Mode t...

Страница 8: ...m the plate behind the modulator blade The plate is located 6 4mm in front of the devices front plane After switching the device off and on always 2cm distance are selected Without the manual E Field...

Страница 9: ...further damage Attention Use only Rechargeable 9V NiMH Battery or an 9V Alkaline Battery Batteries have to be charged outside the device in a suited battery charger Please pay attention to the manufac...

Страница 10: ...of the device The guarantee expires if the device was opened Batteries and accumulators are not allowed in the household waste Every consumer must by law dispose of all batteries and accumulators at...

Страница 11: ...oltage measuring head MK 023 you get a high impedance volt meter with an impedance off 1016 Ohm That takes to measure static voltage at isolated conductive parts up to 4kV Select distance 1cm that wil...

Страница 12: ...Alphanumeric LCD display 4 Metal spacers 5 Measuring head MK023 Specifications Voltage measuring head Dimensions L x W x H Approx 80mm x 40mm x 37mm Weight Approx 80g Measuring voltage Approx 4kV Han...

Страница 13: ...Switch on EFM 023 and wait until Dist 2cm displayed Connect CPS socket to ground connect Hand electrode with Silicon cable to the measure input screw theVoltage measuring head 5 on the spacers replace...

Страница 14: ...Start the walking test by pressing the Start button in the software End the walking test by pressing the Stop button By pressing the Reset button max Values will be erased Scope of Delivery The basic...

Страница 15: ...s on the modulator system must be avoided The use of the device in power plants or comparable areas is prohibited The device can not measure alternating fields 1Hz Ad On facilities Audit Kit 1 CPM Ord...

Страница 16: ...A Ohm Meter TOM 100 with Temperature and humidity Sensor TF 100 Additional Scope of Delivery Plate Electrode 75mm x 150mm 20pF HV Converter 1 100V LC TERA Ohm Meter TOM 100 TOM Surface Measure Electro...

Отзывы: