background image

Dwg Name: 

CL310-1390115ART

  

Dwg No: 

1390115 

     

ECO No: 

20550           

Rev: 

D

Pkg Dwg Ref: 

1290186

 

  

Color Reference: 

N/A

INSTRUCTION MANUAL

ENGLISH

CL

310

FRANÇAIS  pg. 37

ESPAÑOL 

pg. 19

400A AC Auto-Ranging 

Digital Clamp Meter

True RMS

Measurement 
Technology

600V

400A

40M

Ω

•  AUTO-RANGING

•  DATA HOLD

•  RANGE HOLD

•  TEMPERATURE

•  AUDIBLE CONTINUITY

CL310-1390115ART.indd   1

10/1/2015   3:43:24 PM

Содержание CL310

Страница 1: ... Color Reference N A INSTRUCTION MANUAL ENGLISH CL310 FRANÇAIS pg 37 ESPAÑOL pg 19 400A AC Auto Ranging Digital Clamp Meter True RMS Measurement Technology 600V 400A 40MΩ AUTO RANGING DATA HOLD RANGE HOLD TEMPERATURE AUDIBLE CONTINUITY CL310 1390115ART indd 1 10 1 2015 3 43 24 PM ...

Страница 2: ...low 18 C corrections are required when ambient working temp is outside of Accuracy Temp range Dimensions 8 66 x 3 03 x 1 61 220 x 77 x 41 mm Weight 9 88 oz 280 g including batteries Calibration Accurate for one year Standards Conforms to UL 61010 1 UL 61010 2 032 UL 61010 2 033 Certified to CAN CSA C22 2 NO 61010 1 61010 2 032 61010 2 033 IEC EN 61010 1 61010 2 032 61010 2 033 IEC EN 61326 1 Pollu...

Страница 3: ...1 0 8 digits 4 000V 1mV 0 8 3 digits 40 00V 10mV 400 0V 100mV 600V 1V 1 0 3 digits Input Impedance 10MΩ Frequency Range 45 to 400Hz Maximum Input 600V AC RMS or 600V DC AC Current A AC 4 000A 1mA 2 5 30 digits 40 00A 10mA 2 5 10 digits 400 0A 100mA 2 0 10 digits Frequency Range 50 to 60Hz Resistance 400 0Ω 0 1Ω 1 2 5 digits 4 000KΩ 1Ω 1 2 3 digits 40 00kΩ 10Ω 400 0kΩ 100Ω 4 000MΩ 1kΩ 40 00MΩ 10kΩ ...

Страница 4: ...dicates negative polarity Display 3 3 4 digit 4000 Count LCD ELECTRICAL SPECIFICATIONS Function Range Resolution Accuracy Capacitance 40 00nF 0 010nF 4 25 digits 400 0nF 0 100nF 4 8 digits 4 000μF 0 001μF 40 00μF 0 010μF 400 0μF 0 100μF 4 000mF 0 001mF 10 9 digits Maximum Input 600V AC RMS or 600V DC Temperature 40 to 1832 F 1 F 0 F 2 8 12 digits 0 F 2 8 6 digits 40 to 1000 C 1 C 2 8 6 digits Freq...

Страница 5: ...AC RMS or 60V DC Such voltages pose a shock hazard To avoid false readings that can lead to electrical shock replace batteries when a low battery indicator appears Do not attempt to measure resistance or continuity on a live circuit Always adhere to local and national safety codes Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed SY...

Страница 6: ...7 4 ENGLISH 1 4000 count LCD display 7 RANGE button 2 Function selector switch 8 MAX MIN button 3 Clamp 9 Data Hold button 4 COM jack 10 Clamp trigger press to open clamp 5 VΩ jack 11 Arrow markings 6 Backlight button 12 SELECT button 11 9 NOTE There are no user serviceable parts inside meter CL310 1390115ART indd 6 10 1 2015 3 43 26 PM ...

Страница 7: ...le by the function selector switch 2 For voltage it toggles between AC and DC For the other functions it switches between F and C between Hz and Duty cycle and between Continuity Resistance Capacitance and Diode Test The default function for each application is printed on the meter in white the secondary function or functions for each setting is printed on the meter in orange BACKLIGHT Press Backl...

Страница 8: ...isplay updates with that new value 2 Press MAX MIN button 8 for more than one second to return to normal measuring mode DATA HOLD Press HOLD 9 to hold the measurement on the display Press HOLD 9 again to release the display to return to live measuring FUNCTION BUTTONS ENGLISH CONNECTIN Do not test if leads are improperly seated intermittent display readings To ensure p press leads into the input j...

Страница 9: ... proper connection firmly press leads into the input jack completely Lead guard should be flush with the meter s faceplate TESTING IN CAT III CAT IV MEASUREMENT LOCATIONS Ensure the test lead shield is pressed firmly in place Failure to use the CATIII CATIV shield increases arc flash risk TESTING IN CAT II MEASUREMENT LOCATIONS CAT III CAT IV shields may be removed for CAT II locations This will a...

Страница 10: ...the wire passes perpendicularly through the center of the clamp in line with the arrow markings 11 To measure current 1 Rotate the Function Selector switch 2 to the 400 A setting 2 Place clamp around wire The current measurement will be shown in the display NOTE If the measurement is less than 40A rotate the Function Selector switch 2 to the 40 A setting for improved resolution If the measurement ...

Страница 11: ...n the LCD indicates which mode is selected Note AC or DC on the display Apply test leads to the circuit to be tested to measure voltage The meter will auto range to display the measurement in the most appropriate range NOTE If appears on the LCD the test leads are being applied to the circuit in reverse Swap the position of the leads to correct this NOTE When in a voltage setting and the test lead...

Страница 12: ... testing in this mode Ensure that the Continuity Testing icon is visible on the display If not press the SELECT button 12 repeatedly until the icon is shown 2 Remove power from circuit 3 Test for continuity by connecting conductor or circuit with test leads If resistance is measured less than 10Ω an audible signal will sound and display will show a resistance value indicating continuity If circuit...

Страница 13: ...e Press the SELECT button 12 once to enter Resistance testing mode The Resistance icon will appear on the display 2 Remove power from circuit 3 Measure resistance by connecting test leads to circuit The meter will auto range to display the measurement in the most appropriate range NOTE When in a Resistance setting and the test leads are open not connected across a resistor or when a failed resisto...

Страница 14: ... and rotate function selector switch 2 to the Continuity Resistance Capacitance Diode Test setting NOTE The meter defaults to Continuity testing in this mode Press the SELECT button 12 twce to enter Capacitance testing mode The Capacitance icon will appear on the display The meter should read 0 nF with test leads open 2 Remove power from circuit 3 Measure capacitance by connecting test leads acros...

Страница 15: ... leads to diode A reading of 200 800mV on display indicates forward bias OL indicates reverse bias An open device will show OL in both polarities A shorted device will show approximately 0mV Red lead Black lead Red lead Black lead FREQUENCY DUTY CYCLE 1 Insert RED test lead into VΩ jack 5 and BLACK test lead into COM jack 4 and rotate function selector switch 2 to the Frequency Duty Cycle setting ...

Страница 16: ...her F or C appears on the display 2 To measure temperature make contact between the thermocouple tip and the object being measured When thermocouple tip and object are in thermal equilibrium the measurement on the display will stabilize The meter will auto range to display the measurement in the most appropriate range Remove thermocouple before switching meter to other measurement functions The th...

Страница 17: ...ust be replaced 1 Remove screw from battery door 2 Replace 3 x AAA batteries note proper polarity 3 Replace battery door and fasten securely with screw To avoid risk of electric shock disconnect leads from any voltage source before removing battery door To avoid risk of electric shock do not operate meter while battery door is removed CL310 1390115ART indd 17 10 1 2015 3 43 32 PM ...

Страница 18: ...extreme conditions exceeding the limits mentioned in the General Specifications section allow the meter to return to normal operating conditions before using WARRANTY www kleintools com warranty DISPOSAL RECYCLE Do not place equipment and its accessories in the trash Items must be properly disposed of in accordance with local regulations Please see www epa gov or www erecycle org for additional in...

Отзывы: