![Klein Tools 092644692871 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/klein-tools/092644692871/092644692871_instruction-manual_1977216004.webp)
4
OTHER MEASUREMENT APPLICATIONS
Maximum Input:
600V AC RMS or 600V DC
•
Diode Test:
Approx. 1mA, open circuit voltage ~3.0V DC
•
Continuity Check:
Audible signal <10Ω, max current 1.5mA
•
Sampling Frequency:
3 samples per second
•
Auto Power off:
After ~5 minutes of inactivity.
•
Over Limit:
"
OL
" indicated on display
•
Polarity:
"-" on display indicates negative polarity
•
Display:
3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function
Range
Resolution
Accuracy
Capacitance
40.00nF
0.01nF
±(4% + 25 digits)
400.0nF
0.1nF
±(4% + 8 digits)
4.000μF
0.001μF
40.00μF
0.01μF
400.0μF
0.1μF
4.000mF
0.001mF
±(5% + 9 digits)
Maximum Input:
600V AC RMS or 600V DC
Temperature
°F
-40° to 10°F
1°F
±(1.2% + 7 digits)
11° to 1832°F
±(1.2% + 6 digits)
Temperature
°C
-40° to -12°C
1°C
±(1.2% + 4 digits)
-11° to 1000°C
±(1.2% + 3 digits)
Maximum Input:
600V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
≤1000kHz
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input:
600V AC RMS or 600V DC
Voltage Range:
8V to 240V AC RMS
Pulse Width:
>0.1ms, must be zero-crossing signal.
ENGLISH
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
• Before each use verify meter operation by measuring a known
voltage or current.
www.calcert.com
1.800.544.2843
0
5
10
15
20
25
30