3-4
CHAPTER 3 Preparation for Deployment
HydroChart 5000 Sonar Operations and Maintenance Manual
P/N 11210080, Rev. 02
The Sonar Head Unit is mounted to the survey vessel by attaching the mounting
flange at the top of Sonar Head Unit to a standard 6-inch pipe flange or other
mounting surface. A bolt pattern is provided on the mounting flange as shown in
Figure 3-1. For a typical, pole mount type over-the-side installation, this design is
well suited for attaching to the base of a pipe.
CAUTION
Always avoid putting excessive silicon grease on the Subcon
male pins. Apply a light coat of grease, and never put grease into the female
connectors.
NOTE
When installing the Sonar Head Unit, refer to Drawing 14605080 in
APPENDIX B: “Drawings.” for the outline dimensions of the Sonar Head
Unit.
Figure 3-1:
Sonar Head Unit Mounting Flange
NOTE
When attaching the Sonar Head Unit to the mounting surface, it is
important to ensure that the assembly is mounted correctly in the fore/aft
direction. The end of the Sonar Head Unit that faces the bow is labeled
FWD on the neck of the mounting flange as shown in Figure 3-2. An arrow label is
also included.
Figure 3-2:
FWD and Arrow Labels on the Sonar Head Unit Mounting Flange
Four 0.4-inch diameter holes
on a 5-inch bolt circle
6-inch diameter
mounting flange
Содержание HydroChart 5000
Страница 7: ...vii A 6 Cable Pinouts A 10 A 7 NMEA 0183 Formats and Information A 10 APPENDIX B Drawings B 1...
Страница 18: ......
Страница 27: ...Technical Description 1 9 Figure 1 5 HydroChart 5000 Sonar System TPU Electronics Block Diagram...
Страница 36: ......
Страница 54: ......
Страница 77: ...NMEA 0183 Formats and Information A 11...
Страница 80: ...B 2 APPENDIX B Drawings HydroChart 5000 Sonar Operations and Maintenance Manual P N 11210080 Rev 02...
Страница 81: ...B 3...
Страница 82: ...B 4 APPENDIX B Drawings HydroChart 5000 Sonar Operations and Maintenance Manual P N 11210080 Rev 02...