purchased has the controls shown in Figure 17, the charcoal
fi
lters must be
replaced according to use: on the average once every 6 months. If the model
purchased has the controls shown in Figure 18, the charcoal
fi
lters must be
replaced each time the light button (Fig.18S) lamp
fl
ashes (i.e. every 120
hours of operation).
Removing the charcoal
fi
lter/s
: before removing the charcoal
fi
lter/s,
the grid and/or grease
fi
lters will have to be removed following the instructions
shown at point 3 of “Extraction version installation” paragraph. Then remove
the charcoal
fi
lters by turning these until they disengage from the pins (turn
the
fi
lters in the opposite direction indicated by the arrows as shown in Figures
12, 13, or 14).
Lighting
:
Replace it with lamps of the same type; if a lamp is not listed in the table
shown in the “Warning” worksheet, please contact the support center.
- For the model shown in Fig. 20: to change the halogen bulbs open the cover
levering from the proper slots.
CAUTION: Do not handle glass bulb with
bare hands.
- For the model shown in Fig. 21: to replace the bulbs, remove the metal grid
by moving the 2 side fasteners A and unscrew the bulb.
- For the model shown in Fig. 22: to replace the bulbs, remove the
fi
lter/s,
moving the fastener and turning the
fi
lter outwards. Subsequently remove the
metal grid by moving the 2 side fasteners (C). Unscrew the bulb.
MALFUNCTIONS
If something appears not to be working properly, do the following simple checks
before calling Technical Service:
•
The hood is not working
Possible cause (1): Power cord not securely plugged in.
Correction: The hood was never electrically connected by the installer. Call
the electrician/installer.
Possible cause (2): A speed has not been selected.
Correction: Select a speed in the control panel.
If the hood has turned off during normal functioning, check that the power
has not been disconnected and that the omnipolar disconnection device has
not tripped.
•
The blower does not work but the lights do
Possible cause: The blower motor connector is not plugged.
Correction: Locate the blower motor connector and plug it. Check to see if the
fan now works. If the problem persists, call Technical Service.
•
The hood is not operating effectively
Possible cause: Dirty
fi
lters/baf
fl
es.
Correction: Check to be sure the
fi
lter is clean.
For ducting hood and hood with an external motor
Possible cause (1). Ducting requirements inadequate. If your duct length
exceeds the manufacturer’s requirements, hood performance will suffer. Air-
fl
ow will also be reduced if the house duct work is too small or there are too
many elbows in the system.
Comply with the of
fi
cial instructions provided by the competent authorities in
merit when installing the disposal duct (example, the air collected must not be
conveyed into a duct already used to central heatings systems, thermosiphons,
etc.). The room contains air taps.
Contact your installer.
Possible cause (2): Obstruction in duct work.
Correction: make sure nothing is blocking the vent (bird nests or kinks in the
duct work).
Possible cause (3): Damper blade may not be opening.
Correction: Make sure the tape is removed from the damper blades and that
it swings open freely.
For
fi
ltering hood
Possible cause: the charcoal
fi
lter/s is saturated.
Correction: replace the charcoal
fi
lter/s.
•
The lamp does not work
Light spot (LED):
If a lamp is not listed in the table shown in the “Warning” worksheet, please
contact Technical Service.
Incandescent lamps:
Possible cause: The lamp or socket may be defective or a wire could
bedisconnected.
Correction: place the lamp in another socket; if the lamp is not working, replace
with lamp of the same type; if the lamp works, the original socket may be
defective or a wiremay be disconnected. Call Technical Service.
Halogen lamps:
Possible cause: The lamp or socket may be defective or a wire could
bedisconnected.
Correction:replace with lamp of the same type. If the problem persists, call
Technical Service.
•
Remote control not working (where present)
Possible cause (1): Link lost between the remote control and the hood.
Correction: Check to see if the hood works with the control on the hood.
Remove power from the hood at the circuit breaker then reapply power.
Relink the remote control to the hood, following the instructions supplied with
the remote control.
Possible cause (2): Remote battery dead.
Correction: Change the battery.