10
necessary to fit an approved bipolar switch
with a minimum contact opening of no less
than 3mm.
Appliance without plug
Fit an approved plug or an approved bipolar
switch with a minimum contact opening of
not less than 3mm.
The manufacturers are not liable for any
problems caused by the user’s failure to
observer the above instructions.
Systems available
Two systems are available:
Exhaust mode
Vapours are extracted outside through an
exhausting pipe that is affixed to the
connection ring above the hood.
Diameter of the exhausting pipe must be
equal to that of the connection ring.
Attention!
If the hood is supplied with carbon filter,
then it must be removed.
Recirculation mode
The air is filtered through a carbon filter and
recirculated into the room through the grid
on the higher part of the chimney.
Attention!
If the hood is not supplied with carbon
filter, then it must be ordered and
mounted.
GB
Warning!
— The hood cannot be connected to flues of
other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time
of other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
— No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil
could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or
its catching on fire because of failure to
observe the above instructions.
Installation
These minimum distances between hobs
and grease filter must be observed:
Minimum 600 mm - electric hobs
Minimum 700 mm - gas or mixed hobs
Electric connection
Before completing any connection, make
sure the house voltage corresponds with the
voltage indicated on the label affixed inside
the hood
It is advisable to call a qualified technician to
make the electrical connection.
Appliance fitted with plug.
Connect it to a socket which conforms with
current regulations.
If you intend to connect it directly to the
electric mains, remove the plug and fit an
approved bipolar switch with a minimum
contact opening of no less than 3mm.
If the plug is not accessible once it has been
inserted in the socket, it will however be
Содержание Rangehood RH10
Страница 3: ...2 ...
Страница 4: ...3 Mounting the hood Wall model ...
Страница 5: ...4 Mounting the hood Ceiling model ...