7 TECHNICAL 

SPECIFICATIONS 

7.1 Dryer 

ratings 

 

7.1.1 Dryer 

ratings 

230V, 50 Hz, 13A, with 2700 W heater 
 

7.1.2  Drive motor ratings 

220-240 VAC, 50 Hz, 1/3 HP (248.5 W), 3.0 A, 1425 RPM, 40ºC 
ambient, class F insulation.   
 

7.1.3 Bulb 

ratings 

235 VAC, 15 W, type T22, E14 socket  
 

7.1.4 Drum 

volume 

6.25 ft

3

 (U.S. DOE rating) / 6.78 ft

3

 (IEC rating). 

 

7.1.5 Energy 

factor 

EF 

 3.0 lbs./kwh (1.36 kg/kwh). 

Duct length (max.) 

7.1.6 

# 90º Turns / 

Maximum Length 

 Elbows 

Rigid Duct 

Flexible Duct 

20 m 

14 m 

17 m 

11 m 

14.5 m 

9 m 

12 m 

7 m 

9 m 

5 m 

 

7.1.7 Air 

flow 

 

volume flow rate  vs. exhaust duct length 

100

110

120

130

140

150

160

170

180

190

200

210

220

230

240

250

260

270

280

290

300

0

5

10

15

20

exhaust duct length [m] 

 rigid duct 

vo

lu

m

e

 flo

w

 ra

te

 [m

3/

h]

empty

177 
171 
165 
159 
153 
147 
141 
135 
130 
124 
118 
112 
106 
100 

94 
88 
82 
76 
71 
65 
59 

8 kg
Regular/Cotton

4 kg     
Permanent Press

8 kg
Regular/Cotton
with lint filter
blocked 85%

4 kg           
Permanent Press
with lint filter
blocked  85%

(cf

m) 

(ft)

16 

33 

49 

66 

/ 17.6 lbs. 

/ 17.6 lbs. 

/ 8.8 lbs. 

/ 8.8 lbs. 

4”

702_58300000121945_ara_en_a 

Page 21 of 21 

Содержание KED2000

Страница 1: ...t vents 3 2 3 Feet leveling legs 3 3 OPERATION 4 3 1 Controls 4 4 COMPONENTS 5 4 1 Dryer Components 5 5 REPAIR 9 5 1 Disassembly Reassembly 9 5 2 Diagnosing troubleshooting 13 5 3 Dryer noise 14 5 4 C...

Страница 2: ...ning service c Carefully follow all servicing instructions Verify the instructions if there are any that you don t fully understand c Read and heed all Cautions and Warnings on the appliance and those...

Страница 3: ...p connector notch with the vent tab 2 2 2 Installing vent ducts For best drying use shortest possible duct length and fewest of elbows Use the table below when selecting ducting 90 Turns Maximum Lengt...

Страница 4: ...er LED Reminder only to clean the lint filter There is no sensor showing lint levels LED indicator lights Program cycle selector knob Additional options buttons Menu chooses options and Select changes...

Страница 5: ...and a manually resettable hi limit temperature protector NTC temperature sensor Heater terminals Front bearing shield Control module Push red button to reset Hi limit protector Hi limit protector Fan...

Страница 6: ...ally reset by pushing the left plunger in viewing rear of dryer the dryer will not run if the switch hasn t been reset 4 1 5 Air exhaust duct Air exhaust duct connects to the fan and allows exhausting...

Страница 7: ...oor pin Door pin engages the door switch notifying the dryer the door is closed for drying If the door pin is damaged the entire door assembly must be replaced A T 20 screw on the door pin cover can b...

Страница 8: ...lacing the seal make sure all old adhesive is removed and no new adhesive gets onto the drum Any excess adhesive or residue may cause squeaking 4 1 12 Drum with bands Drums have two steel bands around...

Страница 9: ...d knob Don t cut cable mounts cut cable ties holding cables to mounts When reassembling use new cable ties 5 1 3 Top panel worktop Remove two T 20 Torx screws with washers from rear of dryer slide pan...

Страница 10: ...once drum cover has been removed 4 Drum sleeve bearing can be removed from drum cover by removing four T 20 Torx screws Drum sleeve bearing Outer bearing race Drum axle 5 1 6 Heater Drum Drum cover Be...

Страница 11: ...cradle 5 1 8 Front panel and bearing shield 1 Remove fascia panel 5 1 1 If necessary for access remove top panel 5 1 3 2 Remove door and door hinge 3 Remove two T 20 Torx screws at top and bottom of...

Страница 12: ...g fan hold motor shaft not motor rotor fins to avoid damaging fins 5 1 10 Anti Crease end light If the Anti Crease end light is on while the display is off an internal switch S3 on the control board h...

Страница 13: ...utout tripped Clean lint screen and clean lint and other debris from front shield then replace hi limit Also check exhaust duct length of elbows Heating element failed Check voltages to and resistance...

Страница 14: ...f fresh air and then turn dryer off and on again No program selected Select program Light bulb defective light bulb burned out Change light bulb No power supply Guarantee power supply Drum light doesn...

Страница 15: ...Turn dryer off and on again Unsuitable program selected gram and then Select suitable pro turn dryer off and on again Maximum drying time exceeded Clean filter and exhaust air duct Spin laundry at a...

Страница 16: ...diately stop dryer by rota Off position then open do 2 Remove and clean filter 3 Replace filter and let dryer cool down 4 Close door then rotate cycle selector knob to desired cycle and press If the w...

Страница 17: ...tester for example Meratester 5 f can be necessary inspection process with 180 twisted power connector ones again do Inspection Process must be done with cold Appliance to prevent that Heater Element...

Страница 18: ...or LCD segments are illuminating n All LEDs and s CD segments are activated All LEDs and or LCD segments are illuminating successive in 0 5 sec steps All LEDs and or L successive in 0 5 sec steps Sequ...

Страница 19: ...n Off blank 10 1 s On blank Off 11 1 s On Off blank 12 1 s On blank Off 13 1 s On Off blank 14 1 s Off On blank 15 10 s only drying LED ON Counts from 0 30 to 0 20 descending Off 16 10 s Off only Damp...

Страница 20: ...if so ontrol is OK and shouldn t be replaced If heater and motor turn on together during Step 2 relay has failed and control must be changed ay is on ule relay diagnostics on the control If heat g e...

Страница 21: ...lbows Rigid Duct Flexible Duct 0 20 m 14 m 1 17 m 11 m 2 14 5 m 9 m 3 12 m 7 m 4 9 m 5 m 7 1 7 Air flow volume flow rate vs exhaust duct length 100 110 120 130 140 150 160 170 180 190 200 210 220 230...

Отзывы: