Water softening and regeneration system operation
WATER SOFTENER: filling the regeneration chambers
REGENERATION: Salt adjustment and consumption
INTAKE H2O
HARDNESS
?(°F)
SOFTENING
REGULATION
TREATABLE
WATER
QUANTITY
(LITRES)
SALT
CONSUMPTION
PER CYCLE
(GRAMS)
AUTONOMY
WITH 1 KG
OF SALT
(N° OF
CYCLES)
REGENERATION RESINS WASH
<15
1
23
10
16-29
2
16
62
30-44
3
35
28
45-59
4
72
14
60-80
5
84
12
100
With the tub
full, at the end
of the cycle
(excluding
soak). The
chambers
empty in line
with the
setting.
5 x 7 second
pulses of fill
water for a
total of 2.3
litres
WASHING
PERFORMED
AT THE
START OF
EACH
PROGRAMME
(including
soak)