background image

2

 

CHECK DRAIN PUMP AND FAN & DRYING VALVE (WAX BLOCK) NO 1

The 

QUICK, END TIME

 and 

TIME

 LED’s come on alternately. If the absence of low level is

detected after 30 seconds, the following fault code will be displayed over the right 3 digits.

‘d02’

Draining fault (draining duration until low level
greater than 30 seconds)

Note. It is impossible to continue if machine remains at full level.

 

CHECK OF FILLING AND OF EV1

Press 

START

 button, the left 2 digits indicate

‘05’.

QUICK 

LED flashes as long as the level is low.

As soon as L1 is attained, the LED becomes
solid and the test program advances
automatically to the next step.
At this very instant, listen carefully for the click
of the pressure switch. It is possible to open
the door and check the water level in the tank,
then close the door to continue test.
If level L1 is not attained after 6 minutes, the following code will be displayed in the right 3
digits.

‘d01’

Filling fault (L1 not attained after 6 minutes)

Note. It is impossible to continue if machine remains empty.

 

CHECK OF FLOWMETER FILLING

The left 2 digits should already be displaying ‘06’.

END TIME 

LED comes on flashing. Once the

filling is complete, 

END TIME

 LED will become

solid. It is possible to open the door and check the
water level in the tank, then close the door to
continue test.
If value read is abnormal, then the flow meter
filling fault code is displayed as below in the right 3
digits.

‘d05’

Flow meter fault

Note. It is necessary to wait until filling is complete before advancing to the next step.

 

CHECK OF CYCLING PUMP AND MOTORISED FLAP VALVE

Press 

START

 button, the left 2 digits indicate ‘07’.

QUICK 

and 

END TIME

 LED’s come on alternately and the valve operates in an accelerated

alternation. Alternation will be approximately 20 seconds up and 20 seconds down.
Transparent door Part No. 31x5364 can be used to view.
Note. If the valve positioning contact is defective, then the valve motor does not stop and
alternations are more rapid.

 

CHECK OF HEATING (WITH CYCLING)

Press 

START

 button, the left 2 digits indicate ‘08’

During heating the 

END TIME

 LED is flashing. As soon as the board detects a rise by 5°c, the

heating stops and the 

END TIME

 LED comes on solid.

If after 5 minutes heating has not risen 5°c the below fault code will be displayed in the right 3
digits.

‘d03’

Heating fault (Temperature rise less than 5°c
after 5 minutes)

Отзывы: