background image

10

504062

Manufactured (Mobile) Home

Installation . . .

The dryer can be installed in a manufactured (mobile) 
home by following these instructions:

1. IMPORTANT: Gas dryers MUST be 

permanently attached to the floor at the time of 
installation. Order No. 526P3 Dryer Installation 
Kit for a manufactured (mobile) home 
installation. Follow the instructions supplied 
with the kit.

2. Venting—Dryer MUST be exhausted to the 

outdoors.

• The dryer can be exhausted to the outdoors through 

the back, left, right or bottom panel. Gas dryers 
cannot be exhausted out the left side because of the 
burner housing.

• The dryer exhaust duct must be secured to the 

mobile home structure.

• Exhaust ducts MUST NOT be connected with sheet 

metal screws or fasteners which extend into the duct.

• Exhaust duct must not be connected to any other 

duct, vent or chimney.

• Dryer exhaust duct MUST NOT terminate under the 

mobile home.

• For proper operation, it is important that the dryer 

has an ample amount of outside make-up air. The 
free area of any opening for the introduction of 
outside air must be at least 25 in

2

 (163 cm

2

).

• When exhausting the dryer to the outdoors, the dryer 

can be installed with “0” inch clearance at the sides 
and rear. Clearance of the duct from combustible 
construction must be a minimum of 2 inches (5.08 
cm).

• Venting materials are not supplied with the dryer 

(obtain locally).

IMPORTANT: Installation must conform to 
the Manufactured Home Construction and 
Safety Standards, Title 24 CFR, Part 32-80 or 
Standard CAN/CSA-Z240 MH.

To reduce the risk of fire and combustion 
gas accumulation, the dryer MUST BE 
EXHAUSTED TO THE OUTDOORS. Refer to 
Section on Dryer Exhaust Requirements.

W047

WARNING

To reduce the risk of fire, the exhaust duct 
and weather hood MUST be fabricated of a 
material that will not support combustion. 
Rigid or flexible metal pipe is recommended 
for a clothes dryer.

W048

WARNING

Содержание Automatic dryers

Страница 1: ...cal installation in the site shall comply with the latest edition of the Australian Electrical Standards AS3000 SAA wiring rules and such local regulations that might apply The gas dryer installation...

Страница 2: ......

Страница 3: ...Electric Dryers 20 Wiring Diagram Gas Dryers 21 Information for Handy Reference 22 Installer Check Back Cover FOR YOUR SAFETY the information in this manual must be followed to minimize the risk of f...

Страница 4: ...2 504062 Replacement Parts If replacement parts are required contact the source where you purchased your dryer...

Страница 5: ...3 cm 4 0 10 2 cm 15 4 39 1 cm 36 91 4 cm 43 109 2 cm WITH LEVELING LEGS TURNED INTO BASE D312IE3D GAS DRYERS 7 7 19 6 cm 4 0 10 2 cm 23 5 59 7 cm 28 71 1 cm 4 1 1 cm 4 0 10 2 cm 15 4 39 1 cm 36 91 4 c...

Страница 6: ...gle phase electrical supply GAS DRYER Dryer needs a 2 wire plus earth 250 Volt 50 Hertz single phase electrical supply NOTE For more detailed information refer to Section on Electrical Requirements Ga...

Страница 7: ...plastic or thin foil flexible ducting Locate dryer so exhaust duct is as short as possible Be certain old ducts are cleaned before installing your new dryer Use 4 10 2 cm diameter rigid or flexible me...

Страница 8: ...ection at the rear of the dryer Make sure you do not damage the pipe threads when removing the cap 3 Connect to gas supply pipe 4 Tighten all connections securely Turn on gas and check all pipe connec...

Страница 9: ...drum Step 5 Plug in the Dryer Refer to Section on Electrical Requirements and connect the dryer to an electrical power source Step 6 Check Installation Refer to Installer Check on the back cover of t...

Страница 10: ...for approximately five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roarin...

Страница 11: ...er from door panel 3 B A D273PE1C 4 Rotate door panel 180 degrees as shown D276PE1B 5 Remove door strike from door liner and reinstall on opposite side D269PE1C 6 Insert liner under flange on bottom o...

Страница 12: ...st duct MUST NOT terminate under the mobile home For proper operation it is important that the dryer has an ample amount of outside make up air The free area of any opening for the introduction of out...

Страница 13: ...ring rules and such local regulations that might apply This dryer is designed to be operated on a two wire plus earth 240 Volt 50 Hertz single phase circuit fused at 20 amperes Insert the dryer s lead...

Страница 14: ...ng a path of least resistance for electric current The dryer is equipped with a cord having an equipment earthing conductor and a 3 prong earthing plug The plug must be plugged into an appropriate out...

Страница 15: ...t be supplied at 10 1 5 inch 2 5 4 kPa water column pressure and a vent to the outdoors must be provided 4 If local codes allow the use of flexible gas tubing connect the 3 8 inch NPT National Pipe Th...

Страница 16: ...ss of 1 2 psig 3 45 kPa The dryer must be isolated from the gas supply piping system by closing the equipment shutoff valve during any pressure testing of the gas supply piping system at test pressure...

Страница 17: ...w o Closet Door SIDE VIEW A A C A D E B CENTERED AIR OPENINGS G 2 Openings Minimum FRONT VIEW Closet Door F F OUTER WALL OF ENCLOSURE 42 NOTE For new installations locate top of wall vent 42 inches ab...

Страница 18: ...ped with an air exchanger that can accommodate on demand make up air needs in the home These devices can be obtained through your building contractor or building material suppliers A clothes dryer pro...

Страница 19: ...exhaust no kits required Exhausting the dryer through sides or bottom can be accomplished by installing a DK1 Sales Accessory Directional Exhaust Kit 528P3 available as optional equipment at extra co...

Страница 20: ...o position and the two halves can be connected from the front Dryer Airflow Efficient dryer operation requires proper dryer airflow Proper dryer airflow can be evaluated by measuring the static pressu...

Страница 21: ...could be damaged Use only a damp or sudsy cloth for cleaning the control panel Some spray prewash products may harm the finish on the control panel NOTE The wiring diagram is located inside the contro...

Страница 22: ...20 504062 Wiring Diagram Electric Dryer...

Страница 23: ...504062 21 Wiring Diagram Gas Dryer...

Страница 24: ...Purchased Model Number Serial Number Store Name Store Address Phone Number Service Agency Service Agency Address Phone Number NOTE Record the above information and keep your sales slip Model and seria...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...he manual for more detailed information LEVEL CHECK Position and Level the Dryer CHECK Connect Dryer Exhaust System CHECK GAS ONLY Connect Gas Supply Pipe Check for Gas Leaks CHECK Wipe Out Inside of...

Отзывы: