Xor & Xnor 

This logic option works like the OR, except that the main output goes off when all active jacks are 
on. In the Logica XT an unusual 3-input Xor is implemented whose results are different from 
chaining multiple 2-input Xor gates. 

Also, conversely to other simple logic modes, the button is not equal to an input jack. Instead, it 
feeds a cascaded Xor function.  See the logical chain hereafter. 

Out

in 1
in 2
in 3

Manual

stored value

(default = 0)

 

Xor can be used as a “digital ring modulator” such as implemented in the ARP Odyssey and KORG 
MS-20 synthesizers. Feed two inputs with two oscillators to get the effect. 
With 3 oscillators feeding this 3-in Xor, you can create sounds much different from cascading 
multiple 2-input Xor; the div/2 out can even provide melodies out of subtly detuned static pitches! 

Here is the detail of the Xor/Xnor function: 

Input jacks 

Out jack = Xor 

Inv jack = Xnor 

All low 

low 

high 

One or more high, but not all 

high 

low 

All high 

low 

high 

 

 

When only two jacks are connected you get a standard two-input Xor function 

 

When a single jack is connected, the first Xor is bypassed 

 

The manual button inverts the final result 

Even & Odd 

The main output goes on when an even number of inputs – including the button – are on. The 
inverted output works the same for an odd number of inputs. The button defaults to off.  
A sum of zero is considered even.  

This function, made of chained Xor can also do a digital ring modulator, albeit less creative 
musically than the dedicated 3-input Xor function above when used with 3 signals. 

in 1
in 2
in 3

Manual

stored value

(default = 0)

Out

 

Содержание Logica XT

Страница 1: ...D S H 1 High Off Gt Tr S R C Features at a glance 14 modes of operation o 6 basic logic functions o 2 forced states o 6 advanced logic functions The Gater adds up multiple gate signals while maintaini...

Страница 2: ...ing up the current draw of all modules mA separately for each of 5V 12V and 12V rails If any of these 3 sums exceeds the available current of your supply for that voltage do not connect the module to...

Страница 3: ...With simple logic functions these all work in the same way Any signal can be brought to any jack Normalization With simple logic unused jacks automatically get the necessary default value so that it i...

Страница 4: ...active column Manual input button This button acts as a fourth input The default status of the button depends on the logic function selected Where it makes sense this default status can be changed by...

Страница 5: ...ccepted and within that half only levels high enough will produce a logic one on the output So changing the amplitude or the voltage offset of the saw will change the width of the resulting pulse saw...

Страница 6: ...ate sounds much different from cascading multiple 2 input Xor the div 2 out can even provide melodies out of subtly detuned static pitches Here is the detail of the Xor Xnor function Input jacks Out j...

Страница 7: ...ines all inputs as an Or function does but also retriggers the output every time a new gate starts while one or more are already active All inputs work the same the button brings a 4th gate signal The...

Страница 8: ...input 1 Signals may overlap only their rising edge is considered for proper validation The manual button inverts the current state of the output Coin This function offers 3 heads or tails random gener...

Страница 9: ...l be delayed Turning the pot within its first half the LED column indicates the delay as follows LED off 1 input is copied to out on the next clock then up one LED at a time corresponding to 2 3 4 6 8...

Страница 10: ...ne Below lowest Off Off On Input jacks are disabled Button inverts Summary Advanced logic White LED Function Out jack Details Top On On Input jacks are disabled Button inverts 1 2 Gater On if at least...

Страница 11: ...and outputs can withstand signals between 12V and 12V without harm Jack Effective voltage range received or generated CV control input 5V to 5V All outputs 0 or 5V logic levels Input low to high chan...

Отзывы: