64
EN
Power level
1
2
3
4
5
Screw
conveyor
motor
OFF
(1A):050
OFF
(2A):055
OFF
(3A):045
OFF
(4A):040
OFF
(5A):035
ON
(1B):015
ON
(2B):020
ON
(3B):020
ON
(4B):020
ON
(5B):020
Exhaust gas
motor
(1C):018
(2C):018
(3C):017
(4C):016
(5C):016
Ash
cleaning
period
(P23):000
(P27):010
(P31):015
(P35):020
(P39):030
Screw motor:
Minimum adjustable value is 0.1 second. The adjustable value for OFF/
ON is 0-9.9 seconds. (1 A) 050, (1B) 015 means that the screw motor stops for 5.0
seconds and works for 1.5 seconds.
Exhaust engine:
The adjustable value is 001-0035 (155-240 V). The draught decreases
as the number increases. 001 means the strongest draught, 035 means the weakest
draught.
Ash cleaning period
: 000 means OFF, 060 is the highest value. P31:015 ] in the 3rd
power stage means that the exhaust engine runs at maximum power for 15 seconds
after 1 hour to remove the ash.
Note
: The above parameters are for your information only, they change
whenthe calorific value of the pellet changes!
Overload protection
There is a fuse in the mains plug on the rear of the furnace to prevent
overvoltage and overcurrent. If the fuse burns out, have it replaced by a
specialist company with an equivalent standard fuse.
Содержание 10034153
Страница 2: ......
Страница 10: ...10 DE INSTALLATION Ger teansichten...
Страница 48: ...48 EN INSTALLATION Device Views...
Страница 86: ...86 FR INSTALLATION Vues de l appareil...
Страница 124: ...124 ES INSTALACI N Vistas del dispositivo...
Страница 162: ...162 IT INSTALLAZIONE Vista del dispositivo...
Страница 193: ......
Страница 194: ......
Страница 195: ......
Страница 196: ......