Klark Teknik HELIX DN9848 Скачать руководство пользователя страница 14

 

HELIX Remote Control: Hardware Set-up Guide

 

User Guide 

 
 

 14 

  

5

 

S

ERIAL 

C

ONNECTION 

(O

PTION

There is an option to control your system remotely from a laptop PC via an RS-232 connection. 

5.1

 

Serial connection details 

The system set up for serial connection is illustrated in the following diagrams, which show 

DN9340E/DN9344E and DN9848E systems. 

 

 

 

 
 

 

 

5.2

 

Connection Procedure 

 

To connect, set up and configure your system for serial operation 

1

 

Connect the HELIX units in a daisy chain configuration, see section 3.1. 

2

 

Power up the HELIX units and assign each one a unique Comms channel address, as 

follows: 

y

 

On the HELIX unit’s front panel, press and hold the 

HOME (SETUP)

 button to access the 

Comms menu page. 

y

 

Use the left-hand 

DATA ENTRY

 knob to select a unique channel address between 1 and 32. 

y

 

Press 

HOME (SETUP)

 to accept. 

The front panel controls, except the 

HOME (SETUP)

 button, are locked out to facilitate remote 

operation.  The display indicates that the unit is under remote control. 

 

Note

 

The order of the addresses does not need to mirror the order of the daisy chain 

networking, but each unit MUST have a unique comms channel address.

 

 

Содержание HELIX DN9848

Страница 1: ...HELIX Remote Control Hardware Set up Guide...

Страница 2: ......

Страница 3: ...62 741515 Fax 44 1562 745371 Email info uk telex com Website www klarkteknik com HELIX Remote Control Hardware Set up Guide User Guide DOC00061 Issue A August 2007 Telex Communications UK Limited In l...

Страница 4: ...HELIX Remote Control Hardware Set up Guide User Guide 4...

Страница 5: ...RNET CONNECTION 11 4 1 Ethernet connection standard 11 4 2 Ethernet connection wireless option 12 4 3 Configuring the network devices 13 4 3 1 HELIX unit PC configuration 13 4 3 2 RapidE unit PC confi...

Страница 6: ...HELIX Remote Control Hardware Set up Guide User Guide 6...

Страница 7: ...serial All units in a system must be running the same protocol version The protocol version is determined by the first digit in the software version for example if a DN9340E unit was running host soft...

Страница 8: ...laptop and adjust the equalisation while listening to the end effect at any place in the venue Serial option The optional RS 232 serial connection is via the PC PORT on the front panel of the first H...

Страница 9: ...hernet switch or hub Each HELIX Ethernet unit has an ETHERNET two port switch on the rear panel that provides Ethernet connectivity Note When connecting the Ethernet cable to the rear panel of a HELIX...

Страница 10: ...nnecting the HELIX units to an Ethernet switch or hub The following diagrams show systems of HELIX DN9340E DN9344E and DN9848E units with each unit in both systems directly connected to an Ethernet sw...

Страница 11: ...00 or later host code that is version 4 protocol For details on setting up the IP address of the HELIX units please refer to their operator manual For HELIX unit interconnection details refer to Secti...

Страница 12: ...tion option is via an Ethernet cable where one end is connected to the network socket of the wireless access point and the other end is connected to either an Ethernet two port switch on one of the HE...

Страница 13: ...s to any connected HELIX units console Then go on to add a new Ethernet port for the RapidE and assign it to the RAPIDE audio unit To configure the RapidE for multi mode operation Enter the RapidE s s...

Страница 14: ...isy chain configuration see section 3 1 2 Power up the HELIX units and assign each one a unique Comms channel address as follows y On the HELIX unit s front panel press and hold the HOME SETUP button...

Страница 15: ...LGAR menu to locate and open the KTG show file containing the HELIX unit settings 6 Continue the set up in ELGAR referring to the ELGAR Library Manager User Guide by adding a new port and assigning a...

Страница 16: ...to the front panel of the unit and then to the RS 232 port on the laptop PC To connect a single unit USB to front panel The KT RS 232 host cable supplied with every unit is connected to the front pane...

Страница 17: ...ns 2 1 and 4 To connect non Ethernet units in an Ethernet to serial system The non Ethernet units are daisy chained using serial RS 485 cabling The first unit is connected to a Lantronix UDS1100 Ether...

Страница 18: ...al converter using Ethernet cable The serial connector at the other end of the Lantronix converter is then connected to the first non Ethernet unit via serial RS 485 cabling All of the non Ethernet un...

Страница 19: ...ble Connect the first unit to the PC using any of the methods shown in Section 6 1 To connect any combination of Ethernet units serial to Ethernet Connect any combination of Ethernet units together us...

Страница 20: ...system provides fast operation while the serial provides slow operation In the Ethernet system connect the Ethernet units together with Ethernet cable using one of the options in Section 3 Connect th...

Страница 21: ...idE s eight external ports can be used for any connection Each external port connection that connects HELIX units is treated as a single network Note So that the networks can run on different protocol...

Страница 22: ...HELIX Remote Control Hardware Set up Guide User Guide 22...

Отзывы: