36
37
Technical Data
Accuracy of measurement
Volt :
± 3% of measurement
1) 2) 3)
Amperes :
± 3 % of measurement ± 0,002 A
1) 2) 3)
Watt :
± 3 % of measurement ± 1
W
1) 2) 3)
KWh :
± 3 % of measurement ± 0,1 kWh
1) 2) 3)
Factor :
± 0,1 % power factor measured
0,7 =< cos =< 1,0
2) 4)
Declaration of Conformity
E44395_Power meter_PT_IM_PRINT.indd 36-37
Input voltage / output voltage: 230 V ~ / 50 Hz
Power consumption: Max. 16
Range voltage: 190 V - 270 V
Current range: 0.01 A - A 19.999
Power range: 1 W - 3680 W
Indication of frequency: 46-65 Hz
Resolution: 0.5 W
Measurement of consumption: 0.00 to 9999.99
kWh
Duration of indication: up to 9,999 hours 59
minutes
Since our products are constantly updated and
improved technical changes are possible and
design.
1) Frequency: 46-65 Hz
2) Measurement in a normal room temperature
3) Distortion of voltage/current < 15%
4) Current > = 1.00A/sinusoidal.
Frequency = 50 or 60 Hz.
Without electronic circuits
We guarantee that the product in respect to
the standards required by law
.