47
Power Consumption
W
104
104
104
Standby power
W
5
5
5
Standby loss
W
0.111
0.111
0.111
Range of temperature control
°C
45~85
Max Temperature range
°C
85
Gas volume of the boiler
㎥
0.00846
0.00846
0.00846
The required draught
mbar
0.1
0.1
0.1
Gas side resistance and
combustion chamber pressure
for boilers operating with
positive pressure
mbar
0.2
0.2
0.2
Water resistance
mbar
10K : 380 / 20K : 480
8.2. Combustion specifications
Item
Unit
TURBO
CONDENSING-13
TURBO
CONDENSING-17
TURBO
CONDENSING-21
Thermal output
(condensing)
kW
13.6~16.6
17.8~21.7
21.9~26.8
Thermal output
(Normal)
kW
12.9~15.8
16.7~20.4
20.4~24.9
CO emission rating
Class
1
1
1
NOx emission rating
Class
1
1
1
Smoke level
No.
0
0
0
Exhaust gas temperature
(Normal / Condensing)
°C
85/60
90/65
95 / 70
Exit flue gas mass flow
kg/s
0.0069
0.0093