3.0 Preoperational Procedures
3.1
Air Supply System Requirements
3.1.1
NOTICE!
Pressure and Flow - Verify that the air supply system has capacity to supply your air
hoist with required pressure and flow. Otherwise the hoist may operate poorly or may fail to operate.
See
Section 3.2
.
3.1.2
CAUTION!
Lubrication - The hoist requires lubrication for proper operation. The oil in the air
supply is the primary source of lubrication to the hoist. Therefore, a dedicated air supply lubricator must
be used with the hoist. Refer to
Section 3.3
.
3.1.3
CAUTION!
Air Quality - Good air quality is essential to prevent damage to your hoist and to
ensure its proper operation. The air must be clean and free of debris such as dirt and rust. Refer to
Section 3.4
for filtration requirements. The air must also be dry; free of moisture and water. Refer to
Section 3.5
.
3.2
Air Supply Capacity And Regulation
3.2.1
Capacity - The air supply system must be capable of delivering the required airflow (cfm) to the hoist
inlet port. Without the required airflow the hoist will not operate properly or may not operate at all. See
Section 2.0
for your hoists air consumption requirements. In determining if your system is capable of
supplying the required airflow, consider the following:
Capacity of compressor(s) and tank
Other air consuming equipment
Flow restrictions such as pipes, hoses, valves and fittings
Inadequate capacity will cause a significant drop in pressure when the hoist is operated, and could
cause poor performance or failure to operate.
3.2.2
Regulation - The hoist requires a constant supply of air at a pressure of between 60 and 90 psi. If the
air supply is not regulated or is regulated at a pressure greater than 90 psi, then a regulator must be
used. The regulator may be located anywhere upline of the lubricator in the air supply to the hoist.
3.3
Lubrication
3.3.1
CAUTION!
The hoist must be supplied with its own lubricator. The lubricator must be located as
follows:
1)
Best location
- At the hoist inlet. In this case the lubricator can be either the mist type or drop
type.
2)
Second best location
- No more than 15 feet away from the hoist, at the same elevation or
above the hoist inlet. In this case the mist type lubricator must be used.
3)
Third best location
- No more than 15 feet away below the hoist. In this case the mist type
lubricator must be used.
3.3.2
CAUTION!
The lubricator must be set to deliver the equivalent of 10 to 15 drops of oil per minute
(2 to 3 cc/minute). The hoist’s exhaust will emit a fine oil mist when properly lubricated.
3.4
Filtration
3.4.1
CAUTION!
The air entering the hoist inlet must not contain any particulate greater than 5 microns
in size. Therefore, the hoist must have a 5 micron filter in its air supply. The filter must be upstream of
the lubricator.
Содержание TCR Series
Страница 12: ...12 Figure 2 3 Dimensions for Manipulator TCR250 Air Hoist inches...
Страница 13: ...13 2 3 Part Names Figure 2 4 Hoist Part Identification Diagrams TCR500P 500C 1000P 1000C...
Страница 14: ...14 Figure 2 5 Hoist Part Identification Diagrams TCR 1000P2 1000C2 2000P2 2000C2...
Страница 16: ...16 Top hook Bottom hook Figure 2 8 Hoist Part Identification Diagrams TCR250C...
Страница 17: ...17 Top hook Bottom hook Figure 2 9 Hoist Part Identification Diagrams TCR250P...
Страница 18: ...18 Top hook Bottom hook Figure 2 10 Hoist Part Identification Diagrams TCR250M...
Страница 51: ...Kito Air Hoists Parts List...
Страница 52: ...TCR250 MAIN BODY 52 9 0 Parts List TCR250 Main Body...
Страница 54: ...TCR250 VALVE BODY 54 TCR250 Valve Body...
Страница 56: ...TCR250 MANIPULATOR CONTROL 56 TCR250M Manipulator Control...
Страница 58: ...TCR500 MAIN BODY TCR500 Main Body TCR500 Main Body 58...
Страница 60: ...TCR1000 2 Main Body TCR1000 2 Main Body 60...
Страница 62: ...TCR1000 Main Body TCR1000 Main Body 62...
Страница 64: ...TCR2000 2 Main Body TCR2000 2 Main Body 64...
Страница 66: ...TCR3000 Main Body TCR3000 Main Body 66...
Страница 68: ...TCR6000 2 Main Body TCR6000 2 Main Body 68...
Страница 70: ...Cord Control Valve Body Cord Control Valve Body 70...
Страница 72: ...Pendant Control Valve Body 72 Pendant Control Valve Body...