Typical Air Supply Filter, Regulator and Lubricator.
3.6.2
NOTICE
Piping
– Pipe should be sized to accommodate the hoist airflow requirements.
Table 3-1 gives recommended pipe sizes.
Table 3-1 Air Supply Pipe and Hose Sizes
Model
Diameter of Supply Pipe
Diameter of Supply Hose
TCK3000, TCK6000
Inside diameter
1.0 inch or larger
Inside diameter
0.75 inch or larger
3.6.3
NOTICE
Hoses
– The connection from the air supply system piping to the hoist must be
made with a flexible pressure hose. Due to normal line losses in air supply lines:
◼
Do not use hose smaller than specified in Table 3-1, and
◼
Limit the length of the hose to that specified in Figure 3-3.
◼
If your application exceeds these requirements consult factory.
◼
The use of “Quick Couplers” is to be avoided. Quick Couplers restrict the air flow that will affect