background image

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

VENTING REQUIREMENTS

KWVU205Y
KWVU265Y

Electrical:

120-volt, 60-Hz, AC-only, 15-amp.

electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit
is recommended.

30" and 36" Slide-out Vent System

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 4360365 Rev. C

08-08-02

®

3/8

"

(9.5 mm)

BACK OF

VENT HOOD

FRONT OF

VENT HOOD

3-1/4

"

(8.3 cm)

4-3/8

"

(11.1 cm)

10

"

(25.4 cm)

30

"

(76.2 cm) model: 8

"

(20.3 cm)

36

"

(91.4 cm) model: 11

"

(27.9 cm)

30

"

(76.2 cm) model: 26

"

(66.0 cm)

36

"

(91.4 cm) model: 32

"

(81.3 cm)

30

"

(76.2 cm) model: 29-7/8

"

(75.9 cm)

36

"

(91.4 cm) model: 35-7/8

"

(91.1 cm)

66

"

(167.6 cm) maximum distance from upper

cabinet hood mounting surface to floor

24

"

(61 cm) minimum distance from underside

of range hood to cooking surface or countertop

15

"

(38.1 cm) minimum upper cabinet height

13

"

(33 cm) upper cabinet depth

30

"

(76.2 cm) model: 13

"

(33.0 cm)

36

"

(91.4 cm) model: 16

"

(40.6 cm)

9-1/2

"

(24.1 cm) 

glass shelf

extends 

7

"

(17.8 cm)

8

"

(20.3 cm)

9-1/8

"

(23.2 cm)

11

"

(27.9 cm)

1

"

(25.4 mm)

1-5/8”

(41.3 mm)

1-1/4

"

(31.8 mm)

1-7/16

"

(3.6 cm)

1/4

"

(6.4 mm)

2

"

(5.1 cm)

5/8

"

to 2-1/8

"

(1.6 cm to 5.4 cm)

2

"

(5.1 cm)

2-3/8

"

(6.0 cm)

Roof venting

3-1/4" x 10"
(8.3 cm x 25 cm)
vent through 
the roof

Wall venting

3-1/4" x 10"
(8.3 cm x 25 cm)
vent through 
the wall

wall
cap

3-1/4" x 10”
(8.3 cm x 25 cm)
90° elbow

wall
cap

Maximum length  

= 26 ft.

(8 m)

1 — 90° elbow 

=  5 ft.  (1.5 m)

9 ft. (2.8 m) straight 

=  9 ft.  (2.8 m)

1 — wall cap 

=  0 ft. 

(0 m)

Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system = 14 

ft. 

(4.3 

m)

6 ft. (1.8 m)

3 ft.

(0.93 m)

3-1/4" x 10" (8.3 cm x 25 cm)

vent system

Recommended vent system length      

Use 3 1/4" x 10" (8.3 cm x 25 cm) vent with maximum length of 
26 feet (8 m) for vent system. For best performance, use no more
than three 90° elbows. To calculate the length of system you need,
add the equivalent feet (meters) for each vent piece used in the
system. See the following example.

Recommended
standard fittings

3-1/4" x 10" 
(8.3 cm x 25 cm)
90° elbow 
= 5 ft. (1.5 m)

3-1/4" x 10" 
(8.3 cm x 25 cm)
flat elbow 
= 12 ft. (3.7 m)

3-1/4" x 10" 
(8.3 cm x 25 cm)
wall cap 
= 0 ft. (0 m)