INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting 

installation. Read and follow the instructions provided 

with any tools listed here.

Tools needed:

 

Level

 

Drill with 1

1

/

4

" (3.0 cm), 

3

/

8

" (9.5 mm), and 

5

/

16

" (7.9 mm) 

drill bits

 

Pencil

 

Wire stripper or utility knife

 

Tape measure or ruler

 

Pliers

 

Caulking gun and weatherproof caulking compound

 

Vent clamps

 

Jigsaw or keyhole saw

 

Flat-blade screwdriver

 

Metal snips

 

Phillips screwdriver

 

Metric hex key set

Parts needed:

 

Home power supply cable

 

1

/

2

" (12.7 mm) UL Listed or CSA Approved strain relief

 

3 UL Listed wire connectors

For vented installations, you will also need:

 

1 wall or roof cap

 

Metal vent system

For non-vented (recirculating) installations, you will also 

need:

 

Recirculation Kit Part Number W1027063 for non-vented 

(recirculating) installations only. See the “Assistance or 

Service” section to order.

 

Charcoal Filter Kit part number W1027068 for non-vented 

(recirculating) installations only. See the “Assistance or 

Service” section to order.

 

6" (15.2 cm) diameter round metal vent duct - length required 

is determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

 

Hood canopy assembly with ventilator and light bulbs 

installed

 

Vent transition with back draft dampers installed

 

Metal grease filter(s)

 

Vent cover support bracket

 

Mounting template

 

2-piece vent cover

 

4 - 3.5 x 9.5 mm screws

 

4 - 3.5 x 6.5 mm screws

 

2 - 2.9 x 6.5 mm screws

 

6 - 5 x 45 mm mounting screws

 

2 - 8 x 40 mm wall anchors

 

4 - 10 x 60 mm wall anchors

 

4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)

 

Torx

®†  

T20

®†

 adapter

Location Requirements

IMPORTANT: 

Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 

installer’s responsibility to comply with installation clearances 

specified on the model/serial/rating plate. The model/serial/

rating plate is located inside the range hood on the rear wall 

of the range hood.
Canopy hood location should be away from strong draft areas, 

such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. 

Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with a 

maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See the “Electrical 

Requirements” section.
The canopy hood is factory set for venting through the roof 

or wall. For non-vented (recirculating) Installation, see “For 

Non-vented (recirculating) Installations Only” in the “Connect 

Vent System” section. The Recirculation Kit Part Number is 

W1027063. Charcoal filters are also required for non-vented 

(recirculating) installations. The Charcoal Filter Kit Part Number is 

W1027068. See the “Assistance or Service” section to order. 
All openings in ceiling and wall where canopy hood will be 

installed must be sealed.

For Mobile Home Installations:

The installation of this range hood must conform to the 

Manufactured Home Construction Safety Standards, Title 24 

CFR, Part 328 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD, Part 280) or when 

such standard is not applicable, the standard for Manufactured 

Home Installation 1982 (Manufactured Home Sites, Communities 

and Setups) ANSI A225.1/NFPA 501A or latest edition, or with 

local codes.

®

TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

Содержание KVWB400DSS4

Страница 1: ...isit our website at www kitchenaid ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30 76 2 CM ET 36 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 807 6777 ou visitez notre site web à www kitchenaid ca Table of Contents Table des matières 2 LI3ZBD W10674121E IMPORTANT READ AND SAVE THESE INSTRU...

Страница 2: ...ontains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complet...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Страница 4: ...orx T20 adapter Location Requirements IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the range hood on the rear wall of the range hood Canopy hood location should be away from ...

Страница 5: ... not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together Use clamps to seal all joints in the vent system The vent sy...

Страница 6: ...formance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A copy of the above code standards can be obtained from National ...

Страница 7: ...g upper and lower vent cover assembly 1 Position vent cover bracket on wall about 1 8 3 0 mm away from the ceiling 2 Mark the hole locations 3 Drill 2 3 8 9 5 mm holes for 8 x 40 mm wall anchors and insert anchors flush with the wall 4 Attach vent cover support bracket to wall Complete Preparation 1 Determine and make all necessary cuts in the wall for the vent system Install the vent system befor...

Страница 8: ...ating installation only 1 Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit 2 Measure from the bottom of the air deflector to the bottom of the hood outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct over the exhaust...

Страница 9: ...n onto hood and lift upper cover to ceiling and install with 2 2 9 x 6 5 mm screws NOTE For vented installations the upper vent cover may be reversed to hide slots Complete Installation 1 For non vented recirculating installations only install charcoal filters over grille on blower housing See the Range Hood Care section 2 Install metal filters See the Range Hood Care section 3 Check the operation...

Страница 10: ...Speed buttons C D and E set the desired speed and control the sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button 1 To turn the blower on press the blower On Off button B and the desired speed button C D or E 2 To turn the blower off press the blower On Off button B Any of the 3 blower speed buttons can be in the on posi...

Страница 11: ... by making sure the spring release handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place 7 Repeat steps 1 5 for the other filter 8 Close the stainless steel panel Engage the 2 pins in the spring catches to secure Non Vented Recirculating Installation Filters The charcoal filter is not wa...

Страница 12: ... BK WH YL GN BK WH BR BU YL WH RD BK YL WH RD BK BU WH RD BK WH RD BK YL BK BU BR BK RD BU WH WH BK LED BK RD BK LED PUSH BUTTON SWITCH OPERATION FUNCTION OFF LAMPS LOW SPEED MED SPEED HIGH SPEED POSITION NO CONNECTION BROWN YELLOW 1 3 BROWN WHITE 1 4 BROWN RED 1 5 BROWN BLACK 1 6 MOTOR SPECIFICATIONS MOTOR RESISTANCE Ω POWER SUPPLY FREQUENCY POWER ABSORTION 120 VAC 60 Hz 240 W BLUE BLACK BLUE GRE...

Страница 13: ...need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada LP Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www kitchenaid ca Our Consultants ...

Страница 14: ...ation solutions etc 5 Defects or damage caused by the use of non genuine KitchenAid parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by KitchenAid 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the ap...

Страница 15: ...areil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifien...

Страница 16: ...W10674121E 2016 KitchenAid Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 11 16 ...

Отзывы: