Contact a qualified technician to carry out the
appliance electrical connection.

before connecting the warming drawer to the
household electrical system to check its operation,
always make sure the drawer power cable is
correctly fitted and that it is NOT pinched or
caught under or behind the drawer or any coupled
appliance.

power cable replacement must be done by the
After-Sales Service or a qualified technician, with a
cable having the same characteristics as the one
provided by the manufacturer (H05RR-F 3x0.75
mm

2

or higher).

Before electrically connecting the appliance, make
sure the mains power supply matches the rating
plate data.

If in doubt, contact a qualified technician.

Contact a qualified technician familiar with the
local regulations and the additional regulations
issued by the local utility company, and that the
work is carried out in compliance with the same.

Important:

Make sure the appliance is connected

to an approved ground wire, to ensure electrical
safety. If necessary, have the system checked by a
specialized technician. The manufacturer declines
any liability in case of injury or damage resulting
from the lack of or disconnection of the ground
wire.

The ground connection is compulsory by law.

The appliance is designed to be used only when
correctly fitted.

Never open the appliance enclosure. In case of
contact with live wires or if the electrical and
mechanical structure is changed, malfunctioning of
the appliance may occur when in use.

If installation, maintenance or repairs are not
carried out correctly, there can be risks for the user.

The manufacturer declines any liability for such
damage or injury.

During the warranty period, repairs must only be
carried out by the authorized technical service,
otherwise the warranty right is lost.

Installation, repair work and cleaning should be
done only after making sure the appliance is
disconnected from the power supply.

The appliance is disconnected from the power
supply in the following cases:
-

operating the main electrical system omnipolar
switch.

-

operating the main electrical system safety
switch.

For connection to the power supply, a separation
device for each pole must be arranged by the
installer.
Separation devices are switches with contact gap of
at least 3 mm.

The data necessary for the connection is given on
the rating plate. This data must match that of the
power supply.

The manufacturer declines any liability in case
of injury or damage resulting from incorrect
installation, improper or incorrect use of the
appliance.
The manufacturer also declines any liability for
damage (e.g. electric shock) caused by the lack
of or disconnection of the ground wire.

The following cables can be used with this type of
appliance:

TYPES AND MINIMUM DIAMETER OF CABLES

SASO

H05RR-F 3x0.75 mm²
H05VV-F 3x0.75 mm²
H05RN-F 3x0.75 mm²
H05V2V2-F 3x0.75 mm²

H05RR-F 3x1.5 mm²
H05VV-F 3x1.5 mm²
H05RN-F 3x1.5 mm²
H05V2V2-F 3x1.5 mm²

ATTENTION:

ATTENTION:

ATTENTION:

Electrical connection

8

Содержание KSDX 1440

Страница 1: ...Instructions for use ...

Страница 2: ......

Страница 3: ...ting the environment 4 Important safety instructions 5 Before using the warming drawer 6 Appliance fitting 6 Electrical connection 8 Maintenance and cleaning 9 Troubleshooting Guide 10 After sales Service 10 ...

Страница 4: ...ent WEEE By ensuring that this product is properly disposed of the user can help prevent potentially harmful consequences for the environment and human health The symbol on the appliance or accompanying documentation indicates that this product should not be treated as household waste but must be taken to a suitable collection point for the recycling of WEEE For further information on the treatmen...

Страница 5: ...ol Do not touch the warming drawer with wet parts of the body and do not use it when barefoot Do not pull the power cable to unplug it Keep children away from the product and the packing materials to avoid interaction with them if not properly supervised Make sure the electrical cables of other appliances used near the warming drawer do not come into contact with its hot parts Do not store plastic...

Страница 6: ... The coupled appliance cannot be installed before fixing the drawer to the cabinet This appliance must only be fitted and installed by qualified personnel who ensure conditions for its safe use Fix the drawer as shown in the figure Before electrically connecting the appliance make sure the rating plate data matches the mains power supply otherwise the appliance could become damaged Make sure the c...

Страница 7: ...ance depending on the model 7 134 5 116 24 526 550 554 595 141 5 24 In case of 595 cabinet recess height the drawer must be installed with the 4 feet and respective 1 mm washers included in the package in the lower part ...

Страница 8: ...ical and mechanical structure is changed malfunctioning of the appliance may occur when in use If installation maintenance or repairs are not carried out correctly there can be risks for the user The manufacturer declines any liability for such damage or injury During the warranty period repairs must only be carried out by the authorized technical service otherwise the warranty right is lost Insta...

Страница 9: ...l areas will form If one of these products accidentally comes into contact with the warming drawer clean it immediately with a damp cloth Slight differences in color on the front of the appliance are due to the use of different materials such as glass plastic and metal Tempered glass drawer base It is advisable to clean the bottom of the drawer after each use making sure to let it cool This will p...

Страница 10: ... faulty If the problem persists after the above checks contact the nearest After Sales Service For a list of authorized Service Centers contact our call center free of charge at the number 00800 3810 4026 Always specify a brief description of the fault the warming drawer type and exact model the Service number the number after the word Service on the data plate located on the outer right edge of t...

Страница 11: ......

Страница 12: ...GB 5019 500 00024 Printed in Italy n 05 13 ...

Отзывы: