4-10
4.
To remove the auger motor or crush/
cube solenoid:
a) Remove the light shield and the bulb
from the socket.
b) Remove the four hex-head screws from
the auger assembly and pull the as-
sembly forward.
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
Light Shield & Bulb
Auger Assembly
c) Remove the green ground wire screw,
disconnect the electrical harness con-
nector, and remove the auger assem-
bly.
Screws
Screws
Harness Connector
Ground Wire
d) To remove the auger, unscrew the drive
coupler (left-hand threads) and remove
it from the motor shaft.
e) Remove the three auger motor hex-
head screws from the housing.
Drive Coupler
Remove
f) Disconnect the wires from the auger
motor terminals.
g) To remove the crush/cube solenoid,
remove the two hex-head mounting
screws from the housing (see above).
h) Disconnect the wires from the solenoid
terminals.
Auger Motor Wires
Solenoid Screws
Auger Motor
Screw (1 of 3)
Solenoid Wires